FHWA NBI 2024 Inspection record Public-domain dataset

SC 11

Carrying SC 11 over GVILLE WATER WORKS PIPES

14MI NE OF PICKENS, Pickens, South Carolina

Data updated May 2026

FHWA NBI record, refreshed with each annual release.

Poor
35 t Inventory load rating

Bridge Snapshot: SC 11

The SC 11 bridge in Pickens, South Carolina carries SC 11 over GVILLE WATER WORKS PIPES. It was built in 1970, making it 56 years old today. The structure is built primarily of prestressed concrete and spans 4 sections, stretching 54.9 meters (180 feet) end to end. Daily traffic averages 3,300 vehicles, placing it in the moderately-trafficked tier of South Carolina bridges. It is owned and maintained by State Highway Agency.

The latest FHWA inspection records show a deck rating of 6/9, superstructure at 7/9, substructure at 4/9. The weakest component sits in poor condition. At least one major component here scores 4 or below, which produces a Poor condition classification under FHWA's current reporting rules. Its NBI inventory load rating is 35.3 metric tons.

Sourced from the FHWA National Bridge Inventory. See our methodology for refresh cadence and NBI release vintage.

How SC 11 compares

▲ 5.5
Load rating vs South Carolina average (29.8 t)
Top 32%
Higher load rating than 68% of South Carolina bridges
156
Bridges in Pickens · 14 in Poor condition
SC 11 35.3 t
South Carolina average 29.8 t

Live comparison across South Carolina.

Historical Sufficiency Rating

PlainBridge-computed
72.3 / 100 - historical 50–79.9 band
Structural adequacy /55
30.0
Serviceability /30
28.0
Essentiality /15
14.3
Special reductions
0

FHWA discontinued this calculated item; it does not determine current condition, funding eligibility, posting, or closure. How the historical reference is calculated.

Condition Ratings

Deck
6/9
Fair (5–6)
Superstructure
7/9
Good (7–9)
Substructure
4/9
Poor (1–4)
Inventory Load Rating
35.3 t
NBI inventory level (metric tons)
Overall Condition
Poor

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Structural Details

Year Built
1970
Material
Prestressed Concrete
Number of Spans
4
Structure Length
54.9 m (180 ft)
Deck Width
14.5 m (48 ft)
Owner
State Highway Agency
Avg Daily Traffic
3,300 vehicles/day
Structure Number
000000000005838

Condition Analysis

  • The deck (driving surface) rates fair at 6/9, minor deterioration that routine maintenance should address.
  • The superstructure (beams and supports above the deck) is in good condition (7/9), showing no significant deterioration.
  • The substructure (piers and abutments) is in poor condition (4/9), showing advanced deterioration that may require priority repair.

How to read this record

SC 11 is in the federal Poor condition category. That is a component-based result, not a closure order.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Understand what Poor condition does and does not mean before drawing conclusions. Poor condition explained
  • Compare SC 11 against other structures in Pickens and across South Carolina. South Carolina bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for SC 11?

SC 11 in Pickens, South Carolina has a deck rating of 6/9, superstructure rating of 7/9, and substructure rating of 4/9 on the FHWA's 0–9 scale.

How often is SC 11 inspected?

SC 11's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 3,300 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. SC 11 is currently shown as Poor condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for SC 11?

SC 11 has an NBI inventory load rating of 35.3 metric tons.

Who is responsible for maintaining SC 11?

SC 11 is owned and maintained by State Highway Agency.

How old is SC 11 and does age affect safety?

SC 11 was built in 1970, making it 56 years old.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Every figure on PlainBridge is rendered directly from federal source data, no number is typed in by an editor. This page draws directly on federal source data, no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error.