FHWA NBI 2024 Inspection record Public-domain dataset

SC 150

Carrying SC 150 over THICKETTY CREEK

6.5 MI S OF GAFFNEY, Cherokee, South Carolina

Data updated May 2026

FHWA NBI record, refreshed with each annual release.

Poor
24 t Inventory load rating

Bridge Snapshot: SC 150

The SC 150 bridge in Cherokee, South Carolina carries SC 150 over THICKETTY CREEK. It was built in 1973, making it 53 years old today. The structure is built primarily of steel and spans 5 sections, stretching 93.0 meters (305 feet) end to end. Daily traffic averages 2,600 vehicles, placing it in the moderately-trafficked tier of South Carolina bridges. It is owned and maintained by State Highway Agency.

The latest FHWA inspection records show a deck rating of 5/9, superstructure at 4/9, substructure at 5/9. The weakest component sits in poor condition. At least one major component here scores 4 or below, which produces a Poor condition classification under FHWA's current reporting rules. Its NBI inventory load rating is 24.0 metric tons.

Sourced from the FHWA National Bridge Inventory. See our methodology for refresh cadence and NBI release vintage.

How SC 150 compares

▼ 5.8
Load rating vs South Carolina average (29.8 t)
Bottom 35%
Lower load rating than 65% of South Carolina bridges
113
Bridges in Cherokee · 11 in Poor condition
SC 150 24.0 t
South Carolina average 29.8 t

Live comparison across South Carolina.

Historical Sufficiency Rating

PlainBridge-computed
53.4 / 100 - historical 50–79.9 band
Structural adequacy /55
22.1
Serviceability /30
21.0
Essentiality /15
12.4
Special reductions
−2.0

FHWA discontinued this calculated item; it does not determine current condition, funding eligibility, posting, or closure. How the historical reference is calculated.

Condition Ratings

Deck
5/9
Fair (5–6)
Superstructure
4/9
Poor (1–4)
Substructure
5/9
Fair (5–6)
Inventory Load Rating
24.0 t
NBI inventory level (metric tons)
Overall Condition
Poor

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Structural Details

Year Built
1973
Material
Steel
Number of Spans
5
Structure Length
93.0 m (305 ft)
Deck Width
11.4 m (37 ft)
Owner
State Highway Agency
Avg Daily Traffic
2,600 vehicles/day
Structure Number
000000000006247

Condition Analysis

  • The deck (driving surface) is in fair condition (5/9), with minor deterioration that may require routine maintenance.
  • The superstructure (beams and supports above the deck) rates poor at 4/9, advanced deterioration that should be prioritized for repair.
  • At 5/9, the substructure (piers and abutments) shows fair condition, with minor wear flagged for upkeep.

How to read this record

SC 150 is in the federal Poor condition category. That is a component-based result, not a closure order.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Understand what Poor condition does and does not mean before drawing conclusions. Poor condition explained
  • Compare SC 150 against other structures in Cherokee and across South Carolina. South Carolina bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for SC 150?

SC 150 in Cherokee, South Carolina has a deck rating of 5/9, superstructure rating of 4/9, and substructure rating of 5/9 on the FHWA's 0–9 scale.

How often is SC 150 inspected?

SC 150's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 2,600 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. SC 150 is currently shown as Poor condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for SC 150?

SC 150 has an NBI inventory load rating of 24.0 metric tons.

Who is responsible for maintaining SC 150?

SC 150 is owned and maintained by State Highway Agency.

How old is SC 150 and does age affect safety?

SC 150 was built in 1973, making it 53 years old.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Every figure on PlainBridge is rendered directly from federal source data, no number is typed in by an editor. This page draws directly on federal source data, no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error.