FHWA NBI 2024 Inspection record Public-domain dataset

RAMP B I-295

Carrying RAMP B I-295 over BEAVERDAM CREEK

0.15 FR I-295 SBL, Hanover, Virginia

Data updated May 2026

FHWA NBI record, refreshed with each annual release.

Fair
74 t Inventory load rating

Bridge Snapshot: RAMP B I-295

The RAMP B I-295 bridge in Hanover, Virginia carries RAMP B I-295 over BEAVERDAM CREEK. It was built in 1979, making it 47 years old today. The structure is built primarily of steel continuous and spans 3 sections, stretching 50.3 meters (165 feet) end to end. Daily traffic averages 4,586 vehicles, placing it in the moderately-trafficked tier of Virginia bridges. It is owned and maintained by State Highway Agency.

The latest FHWA inspection records show a deck rating of 6/9, superstructure at 6/9, substructure at 6/9. The weakest component sits in fair condition. No reported major component scores in the Poor range under the current federal condition thresholds. Its NBI inventory load rating is 73.5 metric tons.

Sourced from the FHWA National Bridge Inventory. See our methodology for refresh cadence and NBI release vintage.

How RAMP B I-295 compares

▲ 27.5
Load rating vs Virginia average (46.0 t)
Top 11%
Higher load rating than 89% of Virginia bridges
161
Bridges in Hanover · 6 in Poor condition
RAMP B I-295 73.5 t
Virginia average 46.0 t

Live comparison across Virginia.

Historical Sufficiency Rating

PlainBridge-computed
98.4 / 100 - historical 80–100 band
Structural adequacy /55
55.0
Serviceability /30
30.0
Essentiality /15
14.4
Special reductions
−1.0

FHWA discontinued this calculated item; it does not determine current condition, funding eligibility, posting, or closure. How the historical reference is calculated.

Condition Ratings

Deck
6/9
Fair (5–6)
Superstructure
6/9
Fair (5–6)
Substructure
6/9
Fair (5–6)
Inventory Load Rating
73.5 t
NBI inventory level (metric tons)
Overall Condition
Fair

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Structural Details

Year Built
1979
Material
Steel Continuous
Number of Spans
3
Structure Length
50.3 m (165 ft)
Deck Width
10.4 m (34 ft)
Owner
State Highway Agency
Avg Daily Traffic
4,586 vehicles/day
Structure Number
000000000009428

Condition Analysis

  • At 6/9, the deck (driving surface) shows fair condition, with minor wear flagged for upkeep.
  • At 6/9, the superstructure (beams and supports above the deck) shows fair condition, with minor wear flagged for upkeep.
  • At 6/9, the substructure (piers and abutments) shows fair condition, with minor wear flagged for upkeep.

How to read this record

This page shows what the last federal inspection recorded, not whether RAMP B I-295 is safe to cross today. Here is how to use it.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Learn how the 0–9 condition scale and Good/Fair/Poor categories are defined. How condition ratings work
  • Compare RAMP B I-295 against other structures in Hanover and across Virginia. Virginia bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for RAMP B I-295?

RAMP B I-295 in Hanover, Virginia has a deck rating of 6/9, superstructure rating of 6/9, and substructure rating of 6/9 on the FHWA's 0–9 scale.

How often is RAMP B I-295 inspected?

RAMP B I-295's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 4,586 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. RAMP B I-295 is currently shown as Fair condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for RAMP B I-295?

RAMP B I-295 has an NBI inventory load rating of 73.5 metric tons.

Who is responsible for maintaining RAMP B I-295?

RAMP B I-295 is owned and maintained by State Highway Agency.

How old is RAMP B I-295 and does age affect safety?

RAMP B I-295 was built in 1979, making it 47 years old.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Every figure on PlainBridge is rendered directly from federal source data, no number is typed in by an editor. This page draws directly on federal source data, no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error.