FHWA NBI 2024 Inspection record Public-domain dataset

IRR BIA RTE 101

Carrying IRR BIA RTE 101 over SHOTGUN CREEK

15.3 KM SE OF MAIL CAMP, Fremont, Wyoming

Data updated May 2026

FHWA NBI record, refreshed with each annual release.

Poor
20 t Inventory load rating

Bridge Snapshot: IRR BIA RTE 101

The IRR BIA RTE 101 bridge in Fremont, Wyoming carries IRR BIA RTE 101 over SHOTGUN CREEK. It was built in 1951, making it 75 years old today. The structure is built primarily of wood or timber and spans 3 sections, stretching 17.8 meters (58 feet) end to end. Daily traffic averages 30 vehicles, placing it in the lower-traffic tier of Wyoming bridges. It is owned and maintained by Bureau of Indian Affairs.

The latest FHWA inspection records show a deck rating of 4/9, superstructure at 5/9, substructure at 4/9. The weakest component sits in poor condition. Because at least one major component scores 4 or lower, this bridge falls in FHWA's Poor condition category. That category is not a closure order. Its NBI inventory load rating is 20.2 metric tons.

Sourced from the FHWA National Bridge Inventory. See our methodology for refresh cadence and NBI release vintage.

How IRR BIA RTE 101 compares

▼ 13.3
Load rating vs Wyoming average (33.5 t)
Bottom 6%
Lower load rating than 94% of Wyoming bridges
177
Bridges in Fremont · 11 in Poor condition
IRR BIA RTE 101 20.2 t
Wyoming average 33.5 t

Live comparison across Wyoming.

Historical Sufficiency Rating

PlainBridge-computed
39.7 / 100 - historical 20–49.9 band
Structural adequacy /55
16.1
Serviceability /30
9.0
Essentiality /15
14.5
Special reductions
0

FHWA discontinued this calculated item; it does not determine current condition, funding eligibility, posting, or closure. How the historical reference is calculated.

Condition Ratings

Deck
4/9
Poor (1–4)
Superstructure
5/9
Fair (5–6)
Substructure
4/9
Poor (1–4)
Inventory Load Rating
20.2 t
NBI inventory level (metric tons)
Overall Condition
Poor

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Structural Details

Year Built
1951
Material
Wood or Timber
Number of Spans
3
Structure Length
17.8 m (58 ft)
Deck Width
4.7 m (15 ft)
Owner
Bureau of Indian Affairs
Avg Daily Traffic
30 vehicles/day
Structure Number
00000000000C810

Condition Analysis

  • The deck (driving surface) is in poor condition (4/9), showing advanced deterioration that may require priority repair.
  • The superstructure (beams and supports above the deck) rates fair at 5/9, minor deterioration that routine maintenance should address.
  • At 4/9, the substructure (piers and abutments) is in poor shape, with advanced wear flagged for priority repair.

How to read this record

IRR BIA RTE 101 is in the federal Poor condition category. That is a component-based result, not a closure order.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Understand what Poor condition does and does not mean before drawing conclusions. Poor condition explained
  • Compare IRR BIA RTE 101 against other structures in Fremont and across Wyoming. Wyoming bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for IRR BIA RTE 101?

IRR BIA RTE 101 in Fremont, Wyoming has a deck rating of 4/9, superstructure rating of 5/9, and substructure rating of 4/9 on the FHWA's 0–9 scale.

How often is IRR BIA RTE 101 inspected?

IRR BIA RTE 101's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 30 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. IRR BIA RTE 101 is currently shown as Poor condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for IRR BIA RTE 101?

IRR BIA RTE 101 has an NBI inventory load rating of 20.2 metric tons.

Who is responsible for maintaining IRR BIA RTE 101?

IRR BIA RTE 101 is owned and maintained by Bureau of Indian Affairs.

How old is IRR BIA RTE 101 and does age affect safety?

IRR BIA RTE 101 was built in 1951, making it 75 years old.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Every figure on PlainBridge is rendered directly from federal source data, no number is typed in by an editor. This page draws directly on federal source data, no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error.