FHWA NBI 2024 Inspection record Public-domain dataset

IRR BIA RTE N321

Carrying IRR BIA RTE N321 over SAND SPRING CREEK

2.0 MI NW OF CRYSTAL N.M., San Juan, New Mexico

Data updated May 2026

FHWA NBI record, refreshed with each annual release.

Poor
14 t Inventory load rating

Bridge Snapshot: IRR BIA RTE N321

The IRR BIA RTE N321 bridge in San Juan, New Mexico carries IRR BIA RTE N321 over SAND SPRING CREEK. It was built in 1936, making it 90 years old today. The structure is built primarily of wood or timber and spans 4 sections, stretching 23.8 meters (78 feet) end to end. Daily traffic averages 272 vehicles, placing it in the lower-traffic tier of New Mexico bridges. It is owned and maintained by Bureau of Indian Affairs.

The latest FHWA inspection records show a deck rating of 3/9, superstructure at 0/9, substructure at 0/9. The weakest component sits in critical condition. A component scored 4 or below, placing this bridge in the federal Poor condition category rather than declaring it unsafe or closed. Its NBI inventory load rating is 13.7 metric tons.

Sourced from the FHWA National Bridge Inventory. See our methodology for refresh cadence and NBI release vintage.

How IRR BIA RTE N321 compares

▼ 21.1
Load rating vs New Mexico average (34.8 t)
Bottom 3%
Lower load rating than 97% of New Mexico bridges
51
Bridges in San Juan · 4 in Poor condition
IRR BIA RTE N321 13.7 t
New Mexico average 34.8 t

Live comparison across New Mexico.

Historical Sufficiency Rating

PlainBridge-computed
2.0 / 100 - historical under-20 band
Structural adequacy /55
0.0
Serviceability /30
2.0
Essentiality /15
0.0
Special reductions
0

FHWA discontinued this calculated item; it does not determine current condition, funding eligibility, posting, or closure. How the historical reference is calculated.

Condition Ratings

Deck
3/9
Poor (1–4)
Superstructure
0/9
Failed (0)
Substructure
0/9
Failed (0)
Inventory Load Rating
13.7 t
NBI inventory level (metric tons)
Overall Condition
Poor

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Structural Details

Year Built
1936
Material
Wood or Timber
Number of Spans
4
Structure Length
23.8 m (78 ft)
Deck Width
4.3 m (14 ft)
Owner
Bureau of Indian Affairs
Avg Daily Traffic
272 vehicles/day
Structure Number
00000000000N617

Condition Analysis

  • At 3/9, the deck (driving surface) is in poor shape, with advanced wear flagged for priority repair.
  • At 0/9, the superstructure (beams and supports above the deck) is in critical shape, with severe wear requiring urgent action.
  • At 0/9, the substructure (piers and abutments) is in critical shape, with severe wear requiring urgent action.

How to read this record

IRR BIA RTE N321 is in the federal Poor condition category. That is a component-based result, not a closure order.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Understand what Poor condition does and does not mean before drawing conclusions. Poor condition explained
  • Compare IRR BIA RTE N321 against other structures in San Juan and across New Mexico. New Mexico bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for IRR BIA RTE N321?

IRR BIA RTE N321 in San Juan, New Mexico has a deck rating of 3/9, superstructure rating of 0/9, and substructure rating of 0/9 on the FHWA's 0–9 scale.

How often is IRR BIA RTE N321 inspected?

IRR BIA RTE N321's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 272 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. IRR BIA RTE N321 is currently shown as Poor condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for IRR BIA RTE N321?

IRR BIA RTE N321 has an NBI inventory load rating of 13.7 metric tons.

Who is responsible for maintaining IRR BIA RTE N321?

IRR BIA RTE N321 is owned and maintained by Bureau of Indian Affairs.

How old is IRR BIA RTE N321 and does age affect safety?

IRR BIA RTE N321 was built in 1936, making it 90 years old.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Every figure on PlainBridge is rendered directly from federal source data, no number is typed in by an editor. This page draws directly on federal source data, no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error.