FHWA NBI 2024 Inspection record Public-domain dataset

ON TSR 342

Carrying ON TSR 342 over FISHING CREEK

CLINTONDALE, Clinton, Pennsylvania

Data updated May 2026

FHWA NBI record, refreshed with each annual release.

Fair
50 t Inventory load rating

Bridge Snapshot: ON TSR 342

The ON TSR 342 bridge in Clinton, Pennsylvania carries ON TSR 342 over FISHING CREEK. It was built in 1950, making it 76 years old today. It was last reconstructed in 2013, extending its service life. The structure is built primarily of steel and spans 3 sections, stretching 42.4 meters (139 feet) end to end. Daily traffic averages 1,618 vehicles, placing it in the moderately-trafficked tier of Pennsylvania bridges. It is owned and maintained by State Highway Agency.

The latest FHWA inspection records show a deck rating of 8/9, superstructure at 5/9, substructure at 5/9. The weakest component sits in fair condition. All reported major components score above the Poor range. Its NBI inventory load rating is 49.9 metric tons.

Sourced from the FHWA National Bridge Inventory. See our methodology for refresh cadence and NBI release vintage.

How ON TSR 342 compares

▲ 10.6
Load rating vs Pennsylvania average (39.3 t)
Top 15%
Higher load rating than 85% of Pennsylvania bridges
147
Bridges in Clinton · 4 in Poor condition
ON TSR 342 49.9 t
Pennsylvania average 39.3 t

Live comparison across Pennsylvania.

Historical Sufficiency Rating

PlainBridge-computed
87.5 / 100 - historical 80–100 band
Structural adequacy /55
45.0
Serviceability /30
28.0
Essentiality /15
14.5
Special reductions
0

FHWA discontinued this calculated item; it does not determine current condition, funding eligibility, posting, or closure. How the historical reference is calculated.

Condition Ratings

Deck
8/9
Good (7–9)
Superstructure
5/9
Fair (5–6)
Substructure
5/9
Fair (5–6)
Inventory Load Rating
49.9 t
NBI inventory level (metric tons)
Overall Condition
Fair

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Structural Details

Year Built
1950
Last Reconstructed
2013
Material
Steel
Number of Spans
3
Structure Length
42.4 m (139 ft)
Deck Width
10.8 m (35 ft)
Owner
State Highway Agency
Avg Daily Traffic
1,618 vehicles/day
Structure Number
000000000012314

Condition Analysis

  • The deck (driving surface) rates good at 8/9, with no significant deterioration on file.
  • At 5/9, the superstructure (beams and supports above the deck) shows fair condition, with minor wear flagged for upkeep.
  • The substructure (piers and abutments) rates fair at 5/9, minor deterioration that routine maintenance should address.

How to read this record

This page shows what the last federal inspection recorded, not whether ON TSR 342 is safe to cross today. Here is how to use it.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Learn how the 0–9 condition scale and Good/Fair/Poor categories are defined. How condition ratings work
  • Compare ON TSR 342 against other structures in Clinton and across Pennsylvania. Pennsylvania bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for ON TSR 342?

ON TSR 342 in Clinton, Pennsylvania has a deck rating of 8/9, superstructure rating of 5/9, and substructure rating of 5/9 on the FHWA's 0–9 scale.

How often is ON TSR 342 inspected?

ON TSR 342's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 1,618 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. ON TSR 342 is currently shown as Fair condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for ON TSR 342?

ON TSR 342 has an NBI inventory load rating of 49.9 metric tons.

Who is responsible for maintaining ON TSR 342?

ON TSR 342 is owned and maintained by State Highway Agency.

How old is ON TSR 342 and does age affect safety?

ON TSR 342 was built in 1950, making it 76 years old and last reconstructed in 2013.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Every figure on PlainBridge is rendered directly from federal source data, no number is typed in by an editor. This page draws directly on federal source data, no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error.