Poor
37 t Inventory load rating

Bridge Snapshot: SR 3009 Paxton St

The SR 3009 Paxton St bridge in Dauphin, Pennsylvania carries SR 3009 Paxton St over Norfolk Southern RR. It was built in 1929, making it 97 years old today. The structure is built primarily of steel and spans 2 sections, stretching 53.9 meters (177 feet) end to end. Daily traffic averages 17,359 vehicles, placing it in the heavily-trafficked tier of Pennsylvania bridges. It is owned and maintained by Railroad.

The latest FHWA inspection records show a deck rating of 4/9, superstructure at 5/9, substructure at 6/9. The weakest component sits in poor condition. Because at least one major component scores 4 or lower, this bridge falls in FHWA's Poor condition category. That category is not a closure order. Its NBI inventory load rating is 37.2 metric tons.

Sourced from the FHWA National Bridge Inventory. See our methodology for refresh cadence and NBI release vintage.

How SR 3009 Paxton St compares

▼ 2.1
Load rating vs Pennsylvania average (39.3 t)
Bottom 46%
Lower load rating than 54% of Pennsylvania bridges
283
Bridges in Dauphin · 19 in Poor condition
SR 3009 Paxton St 37.2 t
Pennsylvania average 39.3 t

Live comparison across Pennsylvania.

Historical Sufficiency Rating

PlainBridge-computed
70.7 / 100 - historical 50–79.9 band
Structural adequacy /55
45.0
Serviceability /30
22.0
Essentiality /15
6.7
Special reductions
−3.0

FHWA discontinued this calculated item; it does not determine current condition, funding eligibility, posting, or closure. How the historical reference is calculated.

Condition Ratings

Deck
4/9
Poor (1–4)
Superstructure
5/9
Fair (5–6)
Substructure
6/9
Fair (5–6)
Inventory Load Rating
37.2 t
NBI inventory level (metric tons)
Overall Condition
Poor

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Structural Details

Year Built
1929
Material
Steel
Number of Spans
2
Structure Length
53.9 m (177 ft)
Deck Width
17.1 m (56 ft)
Owner
Railroad
Avg Daily Traffic
17,359 vehicles/day
Structure Number
000000000014516

Condition Analysis

  • At 4/9, the deck (driving surface) is in poor shape, with advanced wear flagged for priority repair.
  • The superstructure (beams and supports above the deck) is in fair condition (5/9), with minor deterioration that may require routine maintenance.
  • The substructure (piers and abutments) is in fair condition (6/9), with minor deterioration that may require routine maintenance.

How to read this record

SR 3009 Paxton St is in the federal Poor condition category. That is a component-based result, not a closure order.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Understand what Poor condition does and does not mean before drawing conclusions. Poor condition explained
  • Compare SR 3009 Paxton St against other structures in Dauphin and across Pennsylvania. Pennsylvania bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for SR 3009 Paxton St?

SR 3009 Paxton St in Dauphin, Pennsylvania has a deck rating of 4/9, superstructure rating of 5/9, and substructure rating of 6/9 on the FHWA's 0–9 scale.

How often is SR 3009 Paxton St inspected?

SR 3009 Paxton St's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 17,359 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. SR 3009 Paxton St is currently shown as Poor condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for SR 3009 Paxton St?

SR 3009 Paxton St has an NBI inventory load rating of 37.2 metric tons.

Who is responsible for maintaining SR 3009 Paxton St?

SR 3009 Paxton St is owned and maintained by Railroad.

How old is SR 3009 Paxton St and does age affect safety?

SR 3009 Paxton St was built in 1929, making it 97 years old.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Every figure on PlainBridge is rendered directly from federal source data, no number is typed in by an editor. This page draws directly on federal source data, no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error.