FHWA NBI 2026 Inspection record Public-domain dataset

STC 4747;CNTRL RDG

Carrying STC 4747;CNTRL RDG over BIG CANYON CREEK

0.3 S. PECK, Nez Perce, Idaho

FHWA NBI inspection record for this structure. Condition ratings, inventory load rating, span, deck width, and average daily traffic refresh annually with each NBI release.

Fair
14 t Inventory load rating

Bridge Snapshot: STC 4747;CNTRL RDG

The STC 4747;CNTRL RDG bridge in Nez Perce, Idaho carries STC 4747;CNTRL RDG over BIG CANYON CREEK. It was built in 1948, making it 78 years old today. The structure is built primarily of concrete and spans 1 section, stretching 18.9 meters (62 feet) end to end. Daily traffic averages 30 vehicles, placing it in the lower-traffic tier of Idaho bridges. It is owned and maintained by County Highway Agency, the entity responsible for routine inspections and any needed repairs.

The latest FHWA inspection records show a deck rating of 5/9, superstructure at 5/9, substructure at 5/9 on the 0–9 NBI scale, where 9 is excellent and 0 is failed. The weakest component sits in fair condition, which drives the overall status of this bridge. No major component scores in the poor range, so the bridge is not classified as structurally deficient under federal criteria. Its NBI inventory load rating is 13.6 metric tons — the load level the structure is rated to carry at inventory (long-term) level.

In a county that maintains hundreds of NBI-tracked bridges, STC 4747;CNTRL RDG is one data point in a Idaho inventory that FHWA inspects on a two-year cycle (more often when ratings fall). Bridge age alone is not a reliable safety signal — a 78-era structure can outperform a newer one when maintenance is consistent, materials are sound, and traffic loads stay within design limits. Use the condition ratings above, the sufficiency score, and the structurally-deficient flag together to read the bridge's real status, and check the linked county and state pages to see how this bridge ranks against its peers.

Every figure on this page comes directly from the Federal Highway Administration National Bridge Inventory (NBI), the public dataset that catalogs more than 617,000 highway bridges across the United States and is updated annually from the records that each state Department of Transportation submits to the FHWA. The condition codes use the standardized FHWA Recording and Coding Guide, the same scale that determines federal eligibility for the Highway Bridge Program and the Surface Transportation Block Grant set-aside for off-system bridges. A "structurally deficient" classification under those federal criteria is a maintenance and funding flag, never a closure order; states keep deficient bridges open with load posting, weight limits, or accelerated inspection cycles until rehabilitation or replacement is funded. See our methodology for refresh cadence and the exact NBI release vintage powering each record.

How STC 4747;CNTRL RDG compares

▼ 17.7
Load rating vs Idaho average (31.3 t)
Bottom 4%
Lower load rating than 96% of Idaho bridges
19
Bridges in Nez Perce
STC 4747;CNTRL RDG 13.6 t
Idaho average 31.3 t

NBI inventory load rating (metric tons) and structural-deficiency status compared across Idaho, computed live from the FHWA NBI.

Condition Ratings

Deck
5/9
Fair (5–6)
Superstructure
5/9
Fair (5–6)
Substructure
5/9
Fair (5–6)
Inventory Load Rating
13.6 t
NBI inventory level (metric tons)
SD Status
Not SD

Ratings are on a 0–9 scale: 9 = Excellent, 7–8 = Good, 5–6 = Fair, 3–4 = Poor, 0–2 = Critical/Failed. Sufficiency rating (0–100) combines structural adequacy, functional obsolescence, and essentiality.

Structural Details

Year Built
1948
Material
Concrete
Number of Spans
1
Structure Length
18.9 m (62 ft)
Deck Width
8.5 m (28 ft)
Owner
County Highway Agency
Avg Daily Traffic
30 vehicles/day
Structure Number
000000000020230

Location

0.3 S. PECK, Nez Perce, Idaho
46.467806, -116.418222
View on Google Maps ↗

Data Source

Data from the FHWA National Bridge Inventory (NBI). Bridge inspections are required every two years by federal law. Conditions reflect the most recent inspection.

FHWA NBI Program ↗

Condition Analysis

Built in 1948, this bridge is 78 years old. It carries approximately 30 vehicles per day. Based on the most recent FHWA inspection:

  • The deck (driving surface) is in fair condition (5/9), with minor deterioration that may require routine maintenance.
  • The superstructure (beams and supports above the deck) is in fair condition (5/9), with minor deterioration that may require routine maintenance.
  • The substructure (piers and abutments) is in fair condition (5/9), with minor deterioration that may require routine maintenance.

Its NBI inventory load rating is low, indicating a load-restricted structure.

Frequently Asked Questions

What do the condition ratings mean for STC 4747;CNTRL RDG?

Bridge condition ratings use a 0–9 scale set by the Federal Highway Administration (FHWA). Ratings 7–9 indicate good condition with no significant problems. Ratings 5–6 mean fair condition with minor issues. Ratings 3–4 indicate poor condition requiring repair. Ratings 0–2 are critical, meaning the bridge has serious structural problems. STC 4747;CNTRL RDG in Nez Perce, Idaho has a deck rating of 5/9, superstructure rating of 5/9, and substructure rating of 5/9.

How often is STC 4747;CNTRL RDG inspected?

Federal law requires most highway bridges to be inspected at least every 24 months. Bridges in poor condition or with known issues may be inspected more frequently (every 12 months or less). STC 4747;CNTRL RDG is part of the National Bridge Inventory maintained by the FHWA. With 30 vehicles crossing daily, regular inspection is essential.

What does "structurally deficient" mean for a bridge?

A structurally deficient bridge has at least one major component (deck, superstructure, or substructure) rated 4 or below on the FHWA 0–9 scale. This classification does NOT mean the bridge is unsafe for travel — it means the bridge needs repair, rehabilitation, or eventual replacement. Structurally deficient bridges remain open and are monitored. STC 4747;CNTRL RDG is not classified as structurally deficient.

What is the inventory load rating for STC 4747;CNTRL RDG?

The NBI inventory rating is the load level a bridge is rated to carry for an indefinite period, recorded in metric tons. A lower number means the structure is more load-restricted. STC 4747;CNTRL RDG has an inventory load rating of 13.6 metric tons. It is distinct from the FHWA sufficiency rating, a separate 0–100 funding-eligibility score that this dataset does not include.

Who is responsible for maintaining STC 4747;CNTRL RDG?

Bridge ownership and maintenance responsibility varies — bridges may be owned by state DOTs, counties, cities, railroads, or federal agencies. STC 4747;CNTRL RDG is maintained by County Highway Agency. The FHWA oversees the National Bridge Inventory program and sets inspection standards, but day-to-day maintenance falls to the owning agency. If you notice damage or safety concerns, contact your state DOT or call 911 for emergencies.

How old is STC 4747;CNTRL RDG and does age affect safety?

STC 4747;CNTRL RDG was built in 1948, making it 78 years old. Bridge age alone does not determine safety — condition depends on materials, design, traffic load, maintenance history, and environmental exposure. Many older bridges remain in good condition due to regular maintenance and reconstruction.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A structurally deficient rating does not mean a bridge is closed or unsafe for travel — it indicates the bridge requires repair or replacement. For current closure or safety information, contact your state DOT.

Related