Fair
35 t Inventory load rating

Bridge Snapshot: T-527 ARCH ROCK RD

The T-527 ARCH ROCK RD bridge in Juniata, Pennsylvania carries T-527 ARCH ROCK RD over BIG RUN. It was built in 1991, making it 35 years old today. The structure is built primarily of concrete and spans 1 section, stretching 6.7 meters (22 feet) end to end. Daily traffic averages 400 vehicles, placing it in the lower-traffic tier of Pennsylvania bridges. It is owned and maintained by Town/Township Highway Agency.

The latest FHWA inspection records show a deck rating of 6/9, superstructure at 6/9, substructure at 7/9. The weakest component sits in fair condition. All reported major components score above the Poor range. Its NBI inventory load rating is 35.4 metric tons.

Sourced from the FHWA National Bridge Inventory. See our methodology for refresh cadence and NBI release vintage.

How T-527 ARCH ROCK RD compares

▼ 3.9
Load rating vs Pennsylvania average (39.3 t)
Bottom 39%
Lower load rating than 61% of Pennsylvania bridges
109
Bridges in Juniata · 11 in Poor condition
T-527 ARCH ROCK RD 35.4 t
Pennsylvania average 39.3 t

Live comparison across Pennsylvania.

Historical Sufficiency Rating

PlainBridge-computed
81.9 / 100 - historical 80–100 band
Structural adequacy /55
55.0
Serviceability /30
13.0
Essentiality /15
14.9
Special reductions
−1.0

FHWA discontinued this calculated item; it does not determine current condition, funding eligibility, posting, or closure. How the historical reference is calculated.

Condition Ratings

Deck
6/9
Fair (5–6)
Superstructure
6/9
Fair (5–6)
Substructure
7/9
Good (7–9)
Inventory Load Rating
35.4 t
NBI inventory level (metric tons)
Overall Condition
Fair

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Structural Details

Year Built
1991
Material
Concrete
Number of Spans
1
Structure Length
6.7 m (22 ft)
Deck Width
7.7 m (25 ft)
Owner
Town/Township Highway Agency
Avg Daily Traffic
400 vehicles/day
Structure Number
000000000020333

Condition Analysis

  • At 6/9, the deck (driving surface) shows fair condition, with minor wear flagged for upkeep.
  • At 6/9, the superstructure (beams and supports above the deck) shows fair condition, with minor wear flagged for upkeep.
  • The substructure (piers and abutments) rates good at 7/9, with no significant deterioration on file.

How to read this record

This page shows what the last federal inspection recorded, not whether T-527 ARCH ROCK RD is safe to cross today. Here is how to use it.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Learn how the 0–9 condition scale and Good/Fair/Poor categories are defined. How condition ratings work
  • Compare T-527 ARCH ROCK RD against other structures in Juniata and across Pennsylvania. Pennsylvania bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for T-527 ARCH ROCK RD?

T-527 ARCH ROCK RD in Juniata, Pennsylvania has a deck rating of 6/9, superstructure rating of 6/9, and substructure rating of 7/9 on the FHWA's 0–9 scale.

How often is T-527 ARCH ROCK RD inspected?

T-527 ARCH ROCK RD's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 400 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. T-527 ARCH ROCK RD is currently shown as Fair condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for T-527 ARCH ROCK RD?

T-527 ARCH ROCK RD has an NBI inventory load rating of 35.4 metric tons.

Who is responsible for maintaining T-527 ARCH ROCK RD?

T-527 ARCH ROCK RD is owned and maintained by Town/Township Highway Agency.

How old is T-527 ARCH ROCK RD and does age affect safety?

T-527 ARCH ROCK RD was built in 1991, making it 35 years old.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Every figure on PlainBridge is rendered directly from federal source data, no number is typed in by an editor. This page draws directly on federal source data, no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error.