Poor
8 t Inventory load rating

Bridge Snapshot: CR 624-D-SENTENEY

The CR 624-D-SENTENEY bridge in Poinsett, Arkansas carries CR 624-D-SENTENEY over LANGUILLE RIVER. It was built in 1996, making it 30 years old today. The structure is built primarily of wood or timber and spans 4 sections, stretching 17.9 meters (59 feet) end to end. Daily traffic averages 512 vehicles, placing it in the lower-traffic tier of Arkansas bridges. It is owned and maintained by County Highway Agency.

The latest FHWA inspection records show a deck rating of 4/9, superstructure at 5/9, substructure at 5/9. The weakest component sits in poor condition. A component scored 4 or below, placing this bridge in the federal Poor condition category rather than declaring it unsafe or closed. Its NBI inventory load rating is 8.2 metric tons.

Sourced from the FHWA National Bridge Inventory. See our methodology for refresh cadence and NBI release vintage.

How CR 624-D-SENTENEY compares

▼ 16.7
Load rating vs Arkansas average (24.9 t)
Bottom 2%
Lower load rating than 98% of Arkansas bridges
83
Bridges in Poinsett · 12 in Poor condition
CR 624-D-SENTENEY 8.2 t
Arkansas average 24.9 t

Live comparison across Arkansas.

Historical Sufficiency Rating

PlainBridge-computed
30.0 / 100 - historical 20–49.9 band
Structural adequacy /55
6.3
Serviceability /30
9.5
Essentiality /15
14.2
Special reductions
0

FHWA discontinued this calculated item; it does not determine current condition, funding eligibility, posting, or closure. How the historical reference is calculated.

Condition Ratings

Deck
4/9
Poor (1–4)
Superstructure
5/9
Fair (5–6)
Substructure
5/9
Fair (5–6)
Inventory Load Rating
8.2 t
NBI inventory level (metric tons)
Overall Condition
Poor

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Structural Details

Year Built
1996
Material
Wood or Timber
Number of Spans
4
Structure Length
17.9 m (59 ft)
Deck Width
4.9 m (16 ft)
Owner
County Highway Agency
Avg Daily Traffic
512 vehicles/day
Structure Number
000000000021728

Condition Analysis

  • The deck (driving surface) is in poor condition (4/9), showing advanced deterioration that may require priority repair.
  • The superstructure (beams and supports above the deck) is in fair condition (5/9), with minor deterioration that may require routine maintenance.
  • The substructure (piers and abutments) is in fair condition (5/9), with minor deterioration that may require routine maintenance.

How to read this record

CR 624-D-SENTENEY is in the federal Poor condition category. That is a component-based result, not a closure order.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Understand what Poor condition does and does not mean before drawing conclusions. Poor condition explained
  • Compare CR 624-D-SENTENEY against other structures in Poinsett and across Arkansas. Arkansas bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for CR 624-D-SENTENEY?

CR 624-D-SENTENEY in Poinsett, Arkansas has a deck rating of 4/9, superstructure rating of 5/9, and substructure rating of 5/9 on the FHWA's 0–9 scale.

How often is CR 624-D-SENTENEY inspected?

CR 624-D-SENTENEY's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 512 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. CR 624-D-SENTENEY is currently shown as Poor condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for CR 624-D-SENTENEY?

CR 624-D-SENTENEY has an NBI inventory load rating of 8.2 metric tons.

Who is responsible for maintaining CR 624-D-SENTENEY?

CR 624-D-SENTENEY is owned and maintained by County Highway Agency.

How old is CR 624-D-SENTENEY and does age affect safety?

CR 624-D-SENTENEY was built in 1996, making it 30 years old.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Every figure on PlainBridge is rendered directly from federal source data, no number is typed in by an editor. This page draws directly on federal source data, no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error.