FHWA NBI 2024 Inspection record Public-domain dataset

LEVANS IRON BRIDGE

Carrying LEVANS IRON BRIDGE over LITTLE SWATARA CREEK

0.6 MI NE OF QUARRY ROAD, Lebanon, Pennsylvania

Data updated May 2026

FHWA NBI record, refreshed with each annual release.

Poor
5 t Inventory load rating

Bridge Snapshot: LEVANS IRON BRIDGE

The LEVANS IRON BRIDGE bridge in Lebanon, Pennsylvania carries LEVANS IRON BRIDGE over LITTLE SWATARA CREEK. It was built in 1904, making it 122 years old today. It was last reconstructed in 1960, extending its service life. The structure is built primarily of steel and spans 1 section, stretching 47.9 meters (157 feet) end to end. Daily traffic averages 50 vehicles, placing it in the lower-traffic tier of Pennsylvania bridges. It is owned and maintained by County Highway Agency.

The latest FHWA inspection records show a deck rating of 6/9, superstructure at 1/9, substructure at 5/9. The weakest component sits in critical condition. At least one major component here scores 4 or below, which produces a Poor condition classification under FHWA's current reporting rules. Its NBI inventory load rating is 5.4 metric tons.

Sourced from the FHWA National Bridge Inventory. See our methodology for refresh cadence and NBI release vintage.

How LEVANS IRON BRIDGE compares

▼ 33.9
Load rating vs Pennsylvania average (39.3 t)
Bottom 1%
Lower load rating than 99% of Pennsylvania bridges
221
Bridges in Lebanon · 20 in Poor condition
LEVANS IRON BRIDGE 5.4 t
Pennsylvania average 39.3 t

Live comparison across Pennsylvania.

Historical Sufficiency Rating

PlainBridge-computed
26.2 / 100 - historical 20–49.9 band
Structural adequacy /55
0.0
Serviceability /30
11.3
Essentiality /15
14.9
Special reductions
0

FHWA discontinued this calculated item; it does not determine current condition, funding eligibility, posting, or closure. How the historical reference is calculated.

Condition Ratings

Deck
6/9
Fair (5–6)
Superstructure
1/9
Poor (1–4)
Substructure
5/9
Fair (5–6)
Inventory Load Rating
5.4 t
NBI inventory level (metric tons)
Overall Condition
Poor

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Structural Details

Year Built
1904
Last Reconstructed
1960
Material
Steel
Number of Spans
1
Structure Length
47.9 m (157 ft)
Deck Width
4.9 m (16 ft)
Owner
County Highway Agency
Avg Daily Traffic
50 vehicles/day
Structure Number
000000000022888

Condition Analysis

  • The deck (driving surface) is in fair condition (6/9), with minor deterioration that may require routine maintenance.
  • At 1/9, the superstructure (beams and supports above the deck) is in critical shape, with severe wear requiring urgent action.
  • The substructure (piers and abutments) rates fair at 5/9, minor deterioration that routine maintenance should address.

How to read this record

LEVANS IRON BRIDGE is in the federal Poor condition category. That is a component-based result, not a closure order.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Understand what Poor condition does and does not mean before drawing conclusions. Poor condition explained
  • Compare LEVANS IRON BRIDGE against other structures in Lebanon and across Pennsylvania. Pennsylvania bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for LEVANS IRON BRIDGE?

LEVANS IRON BRIDGE in Lebanon, Pennsylvania has a deck rating of 6/9, superstructure rating of 1/9, and substructure rating of 5/9 on the FHWA's 0–9 scale.

How often is LEVANS IRON BRIDGE inspected?

LEVANS IRON BRIDGE's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 50 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. LEVANS IRON BRIDGE is currently shown as Poor condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for LEVANS IRON BRIDGE?

LEVANS IRON BRIDGE has an NBI inventory load rating of 5.4 metric tons.

Who is responsible for maintaining LEVANS IRON BRIDGE?

LEVANS IRON BRIDGE is owned and maintained by County Highway Agency.

How old is LEVANS IRON BRIDGE and does age affect safety?

LEVANS IRON BRIDGE was built in 1904, making it 122 years old and last reconstructed in 1960.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Every figure on PlainBridge is rendered directly from federal source data, no number is typed in by an editor. This page draws directly on federal source data, no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error.