FHWA NBI 2024 Inspection record Public-domain dataset

S.R. 4012

Carrying S.R. 4012 over OVER BLACKS CREEK

6 MI WEST OF BUTTONWOOD, Lycoming, Pennsylvania

Data updated May 2026

FHWA NBI record, refreshed with each annual release.

Good
48 t Inventory load rating

Bridge Snapshot: S.R. 4012

The S.R. 4012 bridge in Lycoming, Pennsylvania carries S.R. 4012 over OVER BLACKS CREEK. It was built in 1995, making it 31 years old today. The structure is built primarily of prestressed concrete and spans 1 section, stretching 13.4 meters (44 feet) end to end. Daily traffic averages 72 vehicles, placing it in the lower-traffic tier of Pennsylvania bridges. It is owned and maintained by State Highway Agency.

The latest FHWA inspection records show a deck rating of 7/9, superstructure at 7/9, substructure at 7/9. The weakest component sits in good condition. All reported major components score above the Poor range. Its NBI inventory load rating is 48.1 metric tons.

Sourced from the FHWA National Bridge Inventory. See our methodology for refresh cadence and NBI release vintage.

How S.R. 4012 compares

▲ 8.8
Load rating vs Pennsylvania average (39.3 t)
Top 19%
Higher load rating than 81% of Pennsylvania bridges
301
Bridges in Lycoming · 12 in Poor condition
S.R. 4012 48.1 t
Pennsylvania average 39.3 t

Live comparison across Pennsylvania.

Historical Sufficiency Rating

PlainBridge-computed
98.9 / 100 - historical 80–100 band
Structural adequacy /55
55.0
Serviceability /30
30.0
Essentiality /15
14.9
Special reductions
−1.0

FHWA discontinued this calculated item; it does not determine current condition, funding eligibility, posting, or closure. How the historical reference is calculated.

Condition Ratings

Deck
7/9
Good (7–9)
Superstructure
7/9
Good (7–9)
Substructure
7/9
Good (7–9)
Inventory Load Rating
48.1 t
NBI inventory level (metric tons)
Overall Condition
Good

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Structural Details

Year Built
1995
Material
Prestressed Concrete
Number of Spans
1
Structure Length
13.4 m (44 ft)
Deck Width
8.6 m (28 ft)
Owner
State Highway Agency
Avg Daily Traffic
72 vehicles/day
Structure Number
000000000025029

Condition Analysis

  • The deck (driving surface) rates good at 7/9, with no significant deterioration on file.
  • At 7/9, the superstructure (beams and supports above the deck) is in good shape and shows no significant wear.
  • The substructure (piers and abutments) rates good at 7/9, with no significant deterioration on file.

How to read this record

This page shows what the last federal inspection recorded, not whether S.R. 4012 is safe to cross today. Here is how to use it.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Learn how the 0–9 condition scale and Good/Fair/Poor categories are defined. How condition ratings work
  • Compare S.R. 4012 against other structures in Lycoming and across Pennsylvania. Pennsylvania bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for S.R. 4012?

S.R. 4012 in Lycoming, Pennsylvania has a deck rating of 7/9, superstructure rating of 7/9, and substructure rating of 7/9 on the FHWA's 0–9 scale.

How often is S.R. 4012 inspected?

S.R. 4012's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 72 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. S.R. 4012 is currently shown as Good condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for S.R. 4012?

S.R. 4012 has an NBI inventory load rating of 48.1 metric tons.

Who is responsible for maintaining S.R. 4012?

S.R. 4012 is owned and maintained by State Highway Agency.

How old is S.R. 4012 and does age affect safety?

S.R. 4012 was built in 1995, making it 31 years old.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Every figure on PlainBridge is rendered directly from federal source data, no number is typed in by an editor. This page draws directly on federal source data, no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error.