Bridge Snapshot: STC3790;ALLENDALE
The STC3790;ALLENDALE bridge in Canyon, Idaho carries STC3790;ALLENDALE over LOW LINE CANAL. It was built in 1939, making it 87 years old today. It was last reconstructed in 1949, extending its service life. The structure is built primarily of wood or timber and spans 1 section, stretching 7.3 meters (24 feet) end to end. Daily traffic averages 240 vehicles, placing it in the lower-traffic tier of Idaho bridges. It is owned and maintained by Other Local Agencies.
The latest FHWA inspection records show a deck rating of 6/9, superstructure at 6/9, substructure at 6/9. The weakest component sits in fair condition. No reported major component scores in the Poor range under the current federal condition thresholds. Its NBI inventory load rating is 18.1 metric tons.
Sourced from the FHWA National Bridge Inventory. See our methodology for refresh cadence and NBI release vintage.
How STC3790;ALLENDALE compares
Live comparison across Idaho.
Historical Sufficiency Rating
PlainBridge-computedFHWA discontinued this calculated item; it does not determine current condition, funding eligibility, posting, or closure. How the historical reference is calculated.
Condition Ratings
Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.
Structural Details
- Year Built
- 1939
- Last Reconstructed
- 1949
- Material
- Wood or Timber
- Number of Spans
- 1
- Structure Length
- 7.3 m (24 ft)
- Deck Width
- 7.3 m (24 ft)
- Owner
- Other Local Agencies
- Avg Daily Traffic
- 240 vehicles/day
- Structure Number
- 000000000026825
Location
Data Source
FHWA National Bridge Inventory (NBI).
FHWA NBI Program ↗Condition Analysis
- • The deck (driving surface) is in fair condition (6/9), with minor deterioration that may require routine maintenance.
- • The superstructure (beams and supports above the deck) is in fair condition (6/9), with minor deterioration that may require routine maintenance.
- • The substructure (piers and abutments) rates fair at 6/9, minor deterioration that routine maintenance should address.
How to read this record
This page shows what the last federal inspection recorded, not whether STC3790;ALLENDALE is safe to cross today. Here is how to use it.
- NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
- Learn how the 0–9 condition scale and Good/Fair/Poor categories are defined. How condition ratings work
- Compare STC3790;ALLENDALE against other structures in Canyon and across Idaho. Idaho bridges
- Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge
Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.
Frequently Asked Questions
What do the condition ratings mean for STC3790;ALLENDALE?
STC3790;ALLENDALE in Canyon, Idaho has a deck rating of 6/9, superstructure rating of 6/9, and substructure rating of 6/9 on the FHWA's 0–9 scale.
How often is STC3790;ALLENDALE inspected?
STC3790;ALLENDALE's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 240 vehicles per day.
What does “structurally deficient” mean in older bridge reports?
FHWA retired that reported status beginning with the 2018 archive. STC3790;ALLENDALE is currently shown as Fair condition from its component ratings; that category is not a live closure or safety decision.
What is the inventory load rating for STC3790;ALLENDALE?
STC3790;ALLENDALE has an NBI inventory load rating of 18.1 metric tons.
Who is responsible for maintaining STC3790;ALLENDALE?
STC3790;ALLENDALE is owned and maintained by Other Local Agencies.
How old is STC3790;ALLENDALE and does age affect safety?
STC3790;ALLENDALE was built in 1939, making it 87 years old and last reconstructed in 1949.
Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.
Every figure on PlainBridge is rendered directly from federal source data, no number is typed in by an editor. This page draws directly on federal source data, no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error.