FHWA NBI 2024 Inspection record Public-domain dataset

Tin Pot Run Lane

Carrying Tin Pot Run Lane over Tin Pot Run

.10 Fr 651 & .20 To 1201, Fauquier, Virginia

Data updated May 2026

FHWA NBI record, refreshed with each annual release.

Good
70 t Inventory load rating

Bridge Snapshot: Tin Pot Run Lane

The Tin Pot Run Lane bridge in Fauquier, Virginia carries Tin Pot Run Lane over Tin Pot Run. It was built in 2013, making it 13 years old today. The structure is built primarily of prestressed concrete and spans 1 section, stretching 22.3 meters (73 feet) end to end. Daily traffic averages 1,536 vehicles, placing it in the moderately-trafficked tier of Virginia bridges. It is owned and maintained by State Highway Agency.

The latest FHWA inspection records show a deck rating of 7/9, superstructure at 7/9, substructure at 7/9. The weakest component sits in good condition. None of this bridge's reported major components fall into the Poor condition range. Its NBI inventory load rating is 69.9 metric tons.

Sourced from the FHWA National Bridge Inventory. See our methodology for refresh cadence and NBI release vintage.

How Tin Pot Run Lane compares

▲ 23.9
Load rating vs Virginia average (46.0 t)
Top 13%
Higher load rating than 87% of Virginia bridges
229
Bridges in Fauquier · 3 in Poor condition
Tin Pot Run Lane 69.9 t
Virginia average 46.0 t

Live comparison across Virginia.

Historical Sufficiency Rating

PlainBridge-computed
82.8 / 100 - historical 80–100 band
Structural adequacy /55
55.0
Serviceability /30
13.0
Essentiality /15
14.8
Special reductions
0

FHWA discontinued this calculated item; it does not determine current condition, funding eligibility, posting, or closure. How the historical reference is calculated.

Condition Ratings

Deck
7/9
Good (7–9)
Superstructure
7/9
Good (7–9)
Substructure
7/9
Good (7–9)
Inventory Load Rating
69.9 t
NBI inventory level (metric tons)
Overall Condition
Good

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Structural Details

Year Built
2013
Material
Prestressed Concrete
Number of Spans
1
Structure Length
22.3 m (73 ft)
Deck Width
12.8 m (42 ft)
Owner
State Highway Agency
Avg Daily Traffic
1,536 vehicles/day
Structure Number
000000000028013

Condition Analysis

  • At 7/9, the deck (driving surface) is in good shape and shows no significant wear.
  • At 7/9, the superstructure (beams and supports above the deck) is in good shape and shows no significant wear.
  • At 7/9, the substructure (piers and abutments) is in good shape and shows no significant wear.

How to read this record

This page shows what the last federal inspection recorded, not whether Tin Pot Run Lane is safe to cross today. Here is how to use it.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Learn how the 0–9 condition scale and Good/Fair/Poor categories are defined. How condition ratings work
  • Compare Tin Pot Run Lane against other structures in Fauquier and across Virginia. Virginia bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for Tin Pot Run Lane?

Tin Pot Run Lane in Fauquier, Virginia has a deck rating of 7/9, superstructure rating of 7/9, and substructure rating of 7/9 on the FHWA's 0–9 scale.

How often is Tin Pot Run Lane inspected?

Tin Pot Run Lane's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 1,536 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. Tin Pot Run Lane is currently shown as Good condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for Tin Pot Run Lane?

Tin Pot Run Lane has an NBI inventory load rating of 69.9 metric tons.

Who is responsible for maintaining Tin Pot Run Lane?

Tin Pot Run Lane is owned and maintained by State Highway Agency.

How old is Tin Pot Run Lane and does age affect safety?

Tin Pot Run Lane was built in 2013, making it 13 years old.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Every figure on PlainBridge is rendered directly from federal source data, no number is typed in by an editor. This page draws directly on federal source data, no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error.