FHWA NBI 2024 Inspection record Public-domain dataset

T-412 CTY BR # 24

Carrying T-412 CTY BR # 24 over SECHLER RUN

0.2 MI. S OF RIDGEVILLE, Montour, Pennsylvania

Data updated May 2026

FHWA NBI record, refreshed with each annual release.

Fair
25 t Inventory load rating

Bridge Snapshot: T-412 CTY BR # 24

The T-412 CTY BR # 24 bridge in Montour, Pennsylvania carries T-412 CTY BR # 24 over SECHLER RUN. It was built in 1977, making it 49 years old today. The structure is built primarily of wood or timber and spans 1 section, stretching 8.2 meters (27 feet) end to end. Daily traffic averages 500 vehicles, placing it in the lower-traffic tier of Pennsylvania bridges. It is owned and maintained by County Highway Agency.

The latest FHWA inspection records show a deck rating of 5/9, superstructure at 5/9, substructure at 5/9. The weakest component sits in fair condition. No reported major component scores in the Poor range under the current federal condition thresholds. Its NBI inventory load rating is 25.4 metric tons.

Sourced from the FHWA National Bridge Inventory. See our methodology for refresh cadence and NBI release vintage.

How T-412 CTY BR # 24 compares

▼ 13.9
Load rating vs Pennsylvania average (39.3 t)
Bottom 11%
Lower load rating than 89% of Pennsylvania bridges
74
Bridges in Montour · 5 in Poor condition
T-412 CTY BR # 24 25.4 t
Pennsylvania average 39.3 t

Live comparison across Pennsylvania.

Historical Sufficiency Rating

PlainBridge-computed
67.7 / 100 - historical 50–79.9 band
Structural adequacy /55
39.0
Serviceability /30
16.8
Essentiality /15
14.9
Special reductions
−3.0

FHWA discontinued this calculated item; it does not determine current condition, funding eligibility, posting, or closure. How the historical reference is calculated.

Condition Ratings

Deck
5/9
Fair (5–6)
Superstructure
5/9
Fair (5–6)
Substructure
5/9
Fair (5–6)
Inventory Load Rating
25.4 t
NBI inventory level (metric tons)
Overall Condition
Fair

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Structural Details

Year Built
1977
Material
Wood or Timber
Number of Spans
1
Structure Length
8.2 m (27 ft)
Deck Width
7.8 m (26 ft)
Owner
County Highway Agency
Avg Daily Traffic
500 vehicles/day
Structure Number
000000000028437

Condition Analysis

  • The deck (driving surface) rates fair at 5/9, minor deterioration that routine maintenance should address.
  • At 5/9, the superstructure (beams and supports above the deck) shows fair condition, with minor wear flagged for upkeep.
  • At 5/9, the substructure (piers and abutments) shows fair condition, with minor wear flagged for upkeep.

How to read this record

This page shows what the last federal inspection recorded, not whether T-412 CTY BR # 24 is safe to cross today. Here is how to use it.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Learn how the 0–9 condition scale and Good/Fair/Poor categories are defined. How condition ratings work
  • Compare T-412 CTY BR # 24 against other structures in Montour and across Pennsylvania. Pennsylvania bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for T-412 CTY BR # 24?

T-412 CTY BR # 24 in Montour, Pennsylvania has a deck rating of 5/9, superstructure rating of 5/9, and substructure rating of 5/9 on the FHWA's 0–9 scale.

How often is T-412 CTY BR # 24 inspected?

T-412 CTY BR # 24's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 500 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. T-412 CTY BR # 24 is currently shown as Fair condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for T-412 CTY BR # 24?

T-412 CTY BR # 24 has an NBI inventory load rating of 25.4 metric tons.

Who is responsible for maintaining T-412 CTY BR # 24?

T-412 CTY BR # 24 is owned and maintained by County Highway Agency.

How old is T-412 CTY BR # 24 and does age affect safety?

T-412 CTY BR # 24 was built in 1977, making it 49 years old.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Every figure on PlainBridge is rendered directly from federal source data, no number is typed in by an editor. This page draws directly on federal source data, no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error.