FHWA NBI 2024 Inspection record Public-domain dataset

SR 3023,Waterloo

Carrying SR 3023,Waterloo over OVER MILL CREEK

UTICA BOROUGH, Venango, Pennsylvania

Data updated May 2026

FHWA NBI record, refreshed with each annual release.

Poor
32 t Inventory load rating

Bridge Snapshot: SR 3023,Waterloo

The SR 3023,Waterloo bridge in Venango, Pennsylvania carries SR 3023,Waterloo over OVER MILL CREEK. It was built in 1888, making it 138 years old today. It was last reconstructed in 1975, extending its service life. The structure is built primarily of steel and spans 1 section, stretching 18.9 meters (62 feet) end to end. Daily traffic averages 140 vehicles, placing it in the lower-traffic tier of Pennsylvania bridges. It is owned and maintained by State Highway Agency.

The latest FHWA inspection records show a deck rating of 6/9, superstructure at 4/9, substructure at 4/9. The weakest component sits in poor condition. At least one major component here scores 4 or below, which produces a Poor condition classification under FHWA's current reporting rules. Its NBI inventory load rating is 31.8 metric tons.

Sourced from the FHWA National Bridge Inventory. See our methodology for refresh cadence and NBI release vintage.

How SR 3023,Waterloo compares

▼ 7.5
Load rating vs Pennsylvania average (39.3 t)
Bottom 20%
Lower load rating than 80% of Pennsylvania bridges
189
Bridges in Venango · 27 in Poor condition
SR 3023,Waterloo 31.8 t
Pennsylvania average 39.3 t

Live comparison across Pennsylvania.

Historical Sufficiency Rating

PlainBridge-computed
60.0 / 100 - historical 50–79.9 band
Structural adequacy /55
29.8
Serviceability /30
18.3
Essentiality /15
14.9
Special reductions
−3.0

FHWA discontinued this calculated item; it does not determine current condition, funding eligibility, posting, or closure. How the historical reference is calculated.

Condition Ratings

Deck
6/9
Fair (5–6)
Superstructure
4/9
Poor (1–4)
Substructure
4/9
Poor (1–4)
Inventory Load Rating
31.8 t
NBI inventory level (metric tons)
Overall Condition
Poor

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Structural Details

Year Built
1888
Last Reconstructed
1975
Material
Steel
Number of Spans
1
Structure Length
18.9 m (62 ft)
Deck Width
5.7 m (19 ft)
Owner
State Highway Agency
Avg Daily Traffic
140 vehicles/day
Structure Number
000000000033829

Condition Analysis

  • The deck (driving surface) is in fair condition (6/9), with minor deterioration that may require routine maintenance.
  • At 4/9, the superstructure (beams and supports above the deck) is in poor shape, with advanced wear flagged for priority repair.
  • The substructure (piers and abutments) is in poor condition (4/9), showing advanced deterioration that may require priority repair.

How to read this record

SR 3023,Waterloo is in the federal Poor condition category. That is a component-based result, not a closure order.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Understand what Poor condition does and does not mean before drawing conclusions. Poor condition explained
  • Compare SR 3023,Waterloo against other structures in Venango and across Pennsylvania. Pennsylvania bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for SR 3023,Waterloo?

SR 3023,Waterloo in Venango, Pennsylvania has a deck rating of 6/9, superstructure rating of 4/9, and substructure rating of 4/9 on the FHWA's 0–9 scale.

How often is SR 3023,Waterloo inspected?

SR 3023,Waterloo's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 140 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. SR 3023,Waterloo is currently shown as Poor condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for SR 3023,Waterloo?

SR 3023,Waterloo has an NBI inventory load rating of 31.8 metric tons.

Who is responsible for maintaining SR 3023,Waterloo?

SR 3023,Waterloo is owned and maintained by State Highway Agency.

How old is SR 3023,Waterloo and does age affect safety?

SR 3023,Waterloo was built in 1888, making it 138 years old and last reconstructed in 1975.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Every figure on PlainBridge is rendered directly from federal source data, no number is typed in by an editor. This page draws directly on federal source data, no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error.