FHWA NBI 2024 Inspection record Public-domain dataset

SR 0196 TR 196

Carrying SR 0196 TR 196 over BUTTERNUT CREEK

STERLING TWP 1M S SR 3002, Wayne, Pennsylvania

Data updated May 2026

FHWA NBI record, refreshed with each annual release.

Fair
32 t Inventory load rating

Bridge Snapshot: SR 0196 TR 196

The SR 0196 TR 196 bridge in Wayne, Pennsylvania carries SR 0196 TR 196 over BUTTERNUT CREEK. It was built in 1954, making it 72 years old today. The structure is built primarily of concrete and spans 1 section, stretching 10.4 meters (34 feet) end to end. Daily traffic averages 1,175 vehicles, placing it in the moderately-trafficked tier of Pennsylvania bridges. It is owned and maintained by State Highway Agency.

The latest FHWA inspection records show a deck rating of 6/9, superstructure at 5/9, substructure at 6/9. The weakest component sits in fair condition. All reported major components score above the Poor range. Its NBI inventory load rating is 31.8 metric tons.

Sourced from the FHWA National Bridge Inventory. See our methodology for refresh cadence and NBI release vintage.

How SR 0196 TR 196 compares

▼ 7.5
Load rating vs Pennsylvania average (39.3 t)
Bottom 20%
Lower load rating than 80% of Pennsylvania bridges
259
Bridges in Wayne · 81 in Poor condition
SR 0196 TR 196 31.8 t
Pennsylvania average 39.3 t

Live comparison across Pennsylvania.

Historical Sufficiency Rating

PlainBridge-computed
67.1 / 100 - historical 50–79.9 band
Structural adequacy /55
44.8
Serviceability /30
12.0
Essentiality /15
13.3
Special reductions
−3.0

FHWA discontinued this calculated item; it does not determine current condition, funding eligibility, posting, or closure. How the historical reference is calculated.

Condition Ratings

Deck
6/9
Fair (5–6)
Superstructure
5/9
Fair (5–6)
Substructure
6/9
Fair (5–6)
Inventory Load Rating
31.8 t
NBI inventory level (metric tons)
Overall Condition
Fair

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Structural Details

Year Built
1954
Material
Concrete
Number of Spans
1
Structure Length
10.4 m (34 ft)
Deck Width
8.4 m (28 ft)
Owner
State Highway Agency
Avg Daily Traffic
1,175 vehicles/day
Structure Number
000000000035491

Condition Analysis

  • At 6/9, the deck (driving surface) shows fair condition, with minor wear flagged for upkeep.
  • The superstructure (beams and supports above the deck) is in fair condition (5/9), with minor deterioration that may require routine maintenance.
  • The substructure (piers and abutments) is in fair condition (6/9), with minor deterioration that may require routine maintenance.

How to read this record

This page shows what the last federal inspection recorded, not whether SR 0196 TR 196 is safe to cross today. Here is how to use it.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Learn how the 0–9 condition scale and Good/Fair/Poor categories are defined. How condition ratings work
  • Compare SR 0196 TR 196 against other structures in Wayne and across Pennsylvania. Pennsylvania bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for SR 0196 TR 196?

SR 0196 TR 196 in Wayne, Pennsylvania has a deck rating of 6/9, superstructure rating of 5/9, and substructure rating of 6/9 on the FHWA's 0–9 scale.

How often is SR 0196 TR 196 inspected?

SR 0196 TR 196's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 1,175 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. SR 0196 TR 196 is currently shown as Fair condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for SR 0196 TR 196?

SR 0196 TR 196 has an NBI inventory load rating of 31.8 metric tons.

Who is responsible for maintaining SR 0196 TR 196?

SR 0196 TR 196 is owned and maintained by State Highway Agency.

How old is SR 0196 TR 196 and does age affect safety?

SR 0196 TR 196 was built in 1954, making it 72 years old.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Every figure on PlainBridge is rendered directly from federal source data, no number is typed in by an editor. This page draws directly on federal source data, no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error.