FHWA NBI 2024 Inspection record Public-domain dataset

TR 196 EASTON TPK

Carrying TR 196 EASTON TPK over MIDDLE CREEK

LAKE TWP 150' S TR 296, Wayne, Pennsylvania

Data updated May 2026

FHWA NBI record, refreshed with each annual release.

Fair
75 t Inventory load rating

Bridge Snapshot: TR 196 EASTON TPK

The TR 196 EASTON TPK bridge in Wayne, Pennsylvania carries TR 196 EASTON TPK over MIDDLE CREEK. It was built in 1953, making it 73 years old today. It was last reconstructed in 2011, extending its service life. The structure is built primarily of steel and spans 1 section, stretching 19.5 meters (64 feet) end to end. Daily traffic averages 1,607 vehicles, placing it in the moderately-trafficked tier of Pennsylvania bridges. It is owned and maintained by State Highway Agency.

The latest FHWA inspection records show a deck rating of 8/9, superstructure at 7/9, substructure at 6/9. The weakest component sits in fair condition. All reported major components score above the Poor range. Its NBI inventory load rating is 75.3 metric tons.

Sourced from the FHWA National Bridge Inventory. See our methodology for refresh cadence and NBI release vintage.

How TR 196 EASTON TPK compares

▲ 36.0
Load rating vs Pennsylvania average (39.3 t)
Top 3%
Higher load rating than 97% of Pennsylvania bridges
259
Bridges in Wayne · 81 in Poor condition
TR 196 EASTON TPK 75.3 t
Pennsylvania average 39.3 t

Live comparison across Pennsylvania.

Historical Sufficiency Rating

PlainBridge-computed
90.2 / 100 - historical 80–100 band
Structural adequacy /55
55.0
Serviceability /30
20.9
Essentiality /15
14.3
Special reductions
0

FHWA discontinued this calculated item; it does not determine current condition, funding eligibility, posting, or closure. How the historical reference is calculated.

Condition Ratings

Deck
8/9
Good (7–9)
Superstructure
7/9
Good (7–9)
Substructure
6/9
Fair (5–6)
Inventory Load Rating
75.3 t
NBI inventory level (metric tons)
Overall Condition
Fair

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Structural Details

Year Built
1953
Last Reconstructed
2011
Material
Steel
Number of Spans
1
Structure Length
19.5 m (64 ft)
Deck Width
9.6 m (31 ft)
Owner
State Highway Agency
Avg Daily Traffic
1,607 vehicles/day
Structure Number
000000000035494

Condition Analysis

  • At 8/9, the deck (driving surface) is in good shape and shows no significant wear.
  • The superstructure (beams and supports above the deck) is in good condition (7/9), showing no significant deterioration.
  • The substructure (piers and abutments) is in fair condition (6/9), with minor deterioration that may require routine maintenance.

How to read this record

This page shows what the last federal inspection recorded, not whether TR 196 EASTON TPK is safe to cross today. Here is how to use it.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Learn how the 0–9 condition scale and Good/Fair/Poor categories are defined. How condition ratings work
  • Compare TR 196 EASTON TPK against other structures in Wayne and across Pennsylvania. Pennsylvania bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for TR 196 EASTON TPK?

TR 196 EASTON TPK in Wayne, Pennsylvania has a deck rating of 8/9, superstructure rating of 7/9, and substructure rating of 6/9 on the FHWA's 0–9 scale.

How often is TR 196 EASTON TPK inspected?

TR 196 EASTON TPK's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 1,607 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. TR 196 EASTON TPK is currently shown as Fair condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for TR 196 EASTON TPK?

TR 196 EASTON TPK has an NBI inventory load rating of 75.3 metric tons.

Who is responsible for maintaining TR 196 EASTON TPK?

TR 196 EASTON TPK is owned and maintained by State Highway Agency.

How old is TR 196 EASTON TPK and does age affect safety?

TR 196 EASTON TPK was built in 1953, making it 73 years old and last reconstructed in 2011.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Every figure on PlainBridge is rendered directly from federal source data, no number is typed in by an editor. This page draws directly on federal source data, no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error.