FHWA NBI 2024 Inspection record Public-domain dataset

SR 3002

Carrying SR 3002 over BOWMANS CREEK

NOXEN TWP .2 M W TR 29, Wyoming, Pennsylvania

Data updated May 2026

FHWA NBI record, refreshed with each annual release.

Poor
21 t Inventory load rating

Bridge Snapshot: SR 3002

The SR 3002 bridge in Wyoming, Pennsylvania carries SR 3002 over BOWMANS CREEK. It was built in 1933, making it 93 years old today. The structure is built primarily of steel and spans 1 section, stretching 25.0 meters (82 feet) end to end. Daily traffic averages 210 vehicles, placing it in the lower-traffic tier of Pennsylvania bridges. It is owned and maintained by State Highway Agency.

The latest FHWA inspection records show a deck rating of 4/9, superstructure at 4/9, substructure at 4/9. The weakest component sits in poor condition. Because at least one major component scores 4 or lower, this bridge falls in FHWA's Poor condition category. That category is not a closure order. Its NBI inventory load rating is 20.9 metric tons.

Sourced from the FHWA National Bridge Inventory. See our methodology for refresh cadence and NBI release vintage.

How SR 3002 compares

▼ 18.4
Load rating vs Pennsylvania average (39.3 t)
Bottom 7%
Lower load rating than 93% of Pennsylvania bridges
140
Bridges in Wyoming · 31 in Poor condition
SR 3002 20.9 t
Pennsylvania average 39.3 t

Live comparison across Pennsylvania.

Historical Sufficiency Rating

PlainBridge-computed
42.9 / 100 - historical 20–49.9 band
Structural adequacy /55
17.3
Serviceability /30
14.8
Essentiality /15
10.9
Special reductions
0

FHWA discontinued this calculated item; it does not determine current condition, funding eligibility, posting, or closure. How the historical reference is calculated.

Condition Ratings

Deck
4/9
Poor (1–4)
Superstructure
4/9
Poor (1–4)
Substructure
4/9
Poor (1–4)
Inventory Load Rating
20.9 t
NBI inventory level (metric tons)
Overall Condition
Poor

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Structural Details

Year Built
1933
Material
Steel
Number of Spans
1
Structure Length
25.0 m (82 ft)
Deck Width
9.1 m (30 ft)
Owner
State Highway Agency
Avg Daily Traffic
210 vehicles/day
Structure Number
000000000037281

Condition Analysis

  • The deck (driving surface) rates poor at 4/9, advanced deterioration that should be prioritized for repair.
  • The superstructure (beams and supports above the deck) rates poor at 4/9, advanced deterioration that should be prioritized for repair.
  • At 4/9, the substructure (piers and abutments) is in poor shape, with advanced wear flagged for priority repair.

How to read this record

SR 3002 is in the federal Poor condition category. That is a component-based result, not a closure order.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Understand what Poor condition does and does not mean before drawing conclusions. Poor condition explained
  • Compare SR 3002 against other structures in Wyoming and across Pennsylvania. Pennsylvania bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for SR 3002?

SR 3002 in Wyoming, Pennsylvania has a deck rating of 4/9, superstructure rating of 4/9, and substructure rating of 4/9 on the FHWA's 0–9 scale.

How often is SR 3002 inspected?

SR 3002's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 210 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. SR 3002 is currently shown as Poor condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for SR 3002?

SR 3002 has an NBI inventory load rating of 20.9 metric tons.

Who is responsible for maintaining SR 3002?

SR 3002 is owned and maintained by State Highway Agency.

How old is SR 3002 and does age affect safety?

SR 3002 was built in 1933, making it 93 years old.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Every figure on PlainBridge is rendered directly from federal source data, no number is typed in by an editor. This page draws directly on federal source data, no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error.