FHWA NBI 2024 Inspection record Public-domain dataset

SR 3029

Carrying SR 3029 over MILL CREEK

NORTH YORK LOUCKS MILL RD, York, Pennsylvania

Data updated May 2026

FHWA NBI record, refreshed with each annual release.

Fair
35 t Inventory load rating

Bridge Snapshot: SR 3029

The SR 3029 bridge in York, Pennsylvania carries SR 3029 over MILL CREEK. It was built in 1938, making it 88 years old today. It was last reconstructed in 1949, extending its service life. The structure is built primarily of concrete and spans 1 section, stretching 13.4 meters (44 feet) end to end. Daily traffic averages 6,160 vehicles, placing it in the moderately-trafficked tier of Pennsylvania bridges. It is owned and maintained by State Highway Agency.

The latest FHWA inspection records show a deck rating of 6/9, superstructure at 5/9, substructure at 7/9. The weakest component sits in fair condition. All reported major components score above the Poor range. Its NBI inventory load rating is 35.4 metric tons.

Sourced from the FHWA National Bridge Inventory. See our methodology for refresh cadence and NBI release vintage.

How SR 3029 compares

▼ 3.9
Load rating vs Pennsylvania average (39.3 t)
Bottom 39%
Lower load rating than 61% of Pennsylvania bridges
569
Bridges in York · 69 in Poor condition
SR 3029 35.4 t
Pennsylvania average 39.3 t

Live comparison across Pennsylvania.

Historical Sufficiency Rating

PlainBridge-computed
66.3 / 100 - historical 50–79.9 band
Structural adequacy /55
45.0
Serviceability /30
10.0
Essentiality /15
12.3
Special reductions
−1.0

FHWA discontinued this calculated item; it does not determine current condition, funding eligibility, posting, or closure. How the historical reference is calculated.

Condition Ratings

Deck
6/9
Fair (5–6)
Superstructure
5/9
Fair (5–6)
Substructure
7/9
Good (7–9)
Inventory Load Rating
35.4 t
NBI inventory level (metric tons)
Overall Condition
Fair

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Structural Details

Year Built
1938
Last Reconstructed
1949
Material
Concrete
Number of Spans
1
Structure Length
13.4 m (44 ft)
Deck Width
8.6 m (28 ft)
Owner
State Highway Agency
Avg Daily Traffic
6,160 vehicles/day
Structure Number
000000000037852

Condition Analysis

  • The deck (driving surface) is in fair condition (6/9), with minor deterioration that may require routine maintenance.
  • The superstructure (beams and supports above the deck) is in fair condition (5/9), with minor deterioration that may require routine maintenance.
  • At 7/9, the substructure (piers and abutments) is in good shape and shows no significant wear.

How to read this record

This page shows what the last federal inspection recorded, not whether SR 3029 is safe to cross today. Here is how to use it.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Learn how the 0–9 condition scale and Good/Fair/Poor categories are defined. How condition ratings work
  • Compare SR 3029 against other structures in York and across Pennsylvania. Pennsylvania bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for SR 3029?

SR 3029 in York, Pennsylvania has a deck rating of 6/9, superstructure rating of 5/9, and substructure rating of 7/9 on the FHWA's 0–9 scale.

How often is SR 3029 inspected?

SR 3029's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 6,160 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. SR 3029 is currently shown as Fair condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for SR 3029?

SR 3029 has an NBI inventory load rating of 35.4 metric tons.

Who is responsible for maintaining SR 3029?

SR 3029 is owned and maintained by State Highway Agency.

How old is SR 3029 and does age affect safety?

SR 3029 was built in 1938, making it 88 years old and last reconstructed in 1949.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Every figure on PlainBridge is rendered directly from federal source data, no number is typed in by an editor. This page draws directly on federal source data, no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error.