FHWA NBI 2024 Inspection record Public-domain dataset

SR 0006 TR 6

Carrying SR 0006 TR 6 over TUNKHANNOCK CREEK

TUNKHANNOCK BO 268'E TR29, Wyoming, Pennsylvania

Data updated May 2026

FHWA NBI record, refreshed with each annual release.

Good
20 t Inventory load rating

Bridge Snapshot: SR 0006 TR 6

The SR 0006 TR 6 bridge in Wyoming, Pennsylvania carries SR 0006 TR 6 over TUNKHANNOCK CREEK. It was built in 2000, making it 26 years old today. The structure is built primarily of prestressed concrete and spans 5 sections, stretching 190.2 meters (624 feet) end to end. Daily traffic averages 9,327 vehicles, placing it in the moderately-trafficked tier of Pennsylvania bridges. It is owned and maintained by State Highway Agency.

The latest FHWA inspection records show a deck rating of 7/9, superstructure at 8/9, substructure at 7/9. The weakest component sits in good condition. None of this bridge's reported major components fall into the Poor condition range. Its NBI inventory load rating is 20.0 metric tons.

Sourced from the FHWA National Bridge Inventory. See our methodology for refresh cadence and NBI release vintage.

How SR 0006 TR 6 compares

▼ 19.3
Load rating vs Pennsylvania average (39.3 t)
Bottom 7%
Lower load rating than 93% of Pennsylvania bridges
140
Bridges in Wyoming · 31 in Poor condition
SR 0006 TR 6 20.0 t
Pennsylvania average 39.3 t

Live comparison across Pennsylvania.

Historical Sufficiency Rating

PlainBridge-computed
82.2 / 100 - historical 80–100 band
Structural adequacy /55
40.8
Serviceability /30
28.0
Essentiality /15
13.4
Special reductions
0

FHWA discontinued this calculated item; it does not determine current condition, funding eligibility, posting, or closure. How the historical reference is calculated.

Condition Ratings

Deck
7/9
Good (7–9)
Superstructure
8/9
Good (7–9)
Substructure
7/9
Good (7–9)
Inventory Load Rating
20.0 t
NBI inventory level (metric tons)
Overall Condition
Good

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Structural Details

Year Built
2000
Material
Prestressed Concrete
Number of Spans
5
Structure Length
190.2 m (624 ft)
Deck Width
14.3 m (47 ft)
Owner
State Highway Agency
Avg Daily Traffic
9,327 vehicles/day
Structure Number
000000000041497

Condition Analysis

  • At 7/9, the deck (driving surface) is in good shape and shows no significant wear.
  • The superstructure (beams and supports above the deck) is in good condition (8/9), showing no significant deterioration.
  • The substructure (piers and abutments) rates good at 7/9, with no significant deterioration on file.

How to read this record

This page shows what the last federal inspection recorded, not whether SR 0006 TR 6 is safe to cross today. Here is how to use it.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Learn how the 0–9 condition scale and Good/Fair/Poor categories are defined. How condition ratings work
  • Compare SR 0006 TR 6 against other structures in Wyoming and across Pennsylvania. Pennsylvania bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for SR 0006 TR 6?

SR 0006 TR 6 in Wyoming, Pennsylvania has a deck rating of 7/9, superstructure rating of 8/9, and substructure rating of 7/9 on the FHWA's 0–9 scale.

How often is SR 0006 TR 6 inspected?

SR 0006 TR 6's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 9,327 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. SR 0006 TR 6 is currently shown as Good condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for SR 0006 TR 6?

SR 0006 TR 6 has an NBI inventory load rating of 20.0 metric tons.

Who is responsible for maintaining SR 0006 TR 6?

SR 0006 TR 6 is owned and maintained by State Highway Agency.

How old is SR 0006 TR 6 and does age affect safety?

SR 0006 TR 6 was built in 2000, making it 26 years old.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Every figure on PlainBridge is rendered directly from federal source data, no number is typed in by an editor. This page draws directly on federal source data, no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error.