FHWA NBI 2024 Inspection record Public-domain dataset

US 169

Carrying US 169 over BASS CREEK

0.6 mi. S of jct. SR C56, Webster, Iowa

Data updated May 2026

FHWA NBI record, refreshed with each annual release.

Poor
41 t Inventory load rating

Bridge Snapshot: US 169

The US 169 bridge in Webster, Iowa carries US 169 over BASS CREEK. It was built in 1958, making it 68 years old today. The structure is built primarily of prestressed concrete and spans 3 sections, stretching 34.1 meters (112 feet) end to end. Daily traffic averages 4,680 vehicles, placing it in the moderately-trafficked tier of Iowa bridges. It is owned and maintained by State Highway Agency.

The latest FHWA inspection records show a deck rating of 4/9, superstructure at 7/9, substructure at 7/9. The weakest component sits in poor condition. At least one major component here scores 4 or below, which produces a Poor condition classification under FHWA's current reporting rules. Its NBI inventory load rating is 40.5 metric tons.

Sourced from the FHWA National Bridge Inventory. See our methodology for refresh cadence and NBI release vintage.

How US 169 compares

▲ 9.6
Load rating vs Iowa average (30.9 t)
Top 16%
Higher load rating than 84% of Iowa bridges
179
Bridges in Webster · 41 in Poor condition
US 169 40.5 t
Iowa average 30.9 t

Live comparison across Iowa.

Historical Sufficiency Rating

PlainBridge-computed
77.7 / 100 - historical 50–79.9 band
Structural adequacy /55
55.0
Serviceability /30
10.0
Essentiality /15
12.7
Special reductions
0

FHWA discontinued this calculated item; it does not determine current condition, funding eligibility, posting, or closure. How the historical reference is calculated.

Condition Ratings

Deck
4/9
Poor (1–4)
Superstructure
7/9
Good (7–9)
Substructure
7/9
Good (7–9)
Inventory Load Rating
40.5 t
NBI inventory level (metric tons)
Overall Condition
Poor

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Structural Details

Year Built
1958
Material
Prestressed Concrete
Number of Spans
3
Structure Length
34.1 m (112 ft)
Deck Width
11.0 m (36 ft)
Owner
State Highway Agency
Avg Daily Traffic
4,680 vehicles/day
Structure Number
000000000052250

Condition Analysis

  • The deck (driving surface) rates poor at 4/9, advanced deterioration that should be prioritized for repair.
  • The superstructure (beams and supports above the deck) rates good at 7/9, with no significant deterioration on file.
  • At 7/9, the substructure (piers and abutments) is in good shape and shows no significant wear.

How to read this record

US 169 is in the federal Poor condition category. That is a component-based result, not a closure order.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Understand what Poor condition does and does not mean before drawing conclusions. Poor condition explained
  • Compare US 169 against other structures in Webster and across Iowa. Iowa bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for US 169?

US 169 in Webster, Iowa has a deck rating of 4/9, superstructure rating of 7/9, and substructure rating of 7/9 on the FHWA's 0–9 scale.

How often is US 169 inspected?

US 169's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 4,680 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. US 169 is currently shown as Poor condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for US 169?

US 169 has an NBI inventory load rating of 40.5 metric tons.

Who is responsible for maintaining US 169?

US 169 is owned and maintained by State Highway Agency.

How old is US 169 and does age affect safety?

US 169 was built in 1958, making it 68 years old.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Every figure on PlainBridge is rendered directly from federal source data, no number is typed in by an editor. This page draws directly on federal source data, no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error.