FHWA NBI 2024 Inspection record Public-domain dataset

IA 175

Carrying IA 175 over DRAINAGE DITCH #52

0.8 mi. E of jct SR P29, Webster, Iowa

Data updated May 2026

FHWA NBI record, refreshed with each annual release.

Poor
39 t Inventory load rating

Bridge Snapshot: IA 175

The IA 175 bridge in Webster, Iowa carries IA 175 over DRAINAGE DITCH #52. It was built in 1953, making it 73 years old today. The structure is built primarily of steel and spans 1 section, stretching 9.8 meters (32 feet) end to end. Daily traffic averages 960 vehicles, placing it in the lower-traffic tier of Iowa bridges. It is owned and maintained by State Highway Agency.

The latest FHWA inspection records show a deck rating of 4/9, superstructure at 6/9, substructure at 6/9. The weakest component sits in poor condition. Because at least one major component scores 4 or lower, this bridge falls in FHWA's Poor condition category. That category is not a closure order. Its NBI inventory load rating is 38.6 metric tons.

Sourced from the FHWA National Bridge Inventory. See our methodology for refresh cadence and NBI release vintage.

How IA 175 compares

▲ 7.7
Load rating vs Iowa average (30.9 t)
Top 20%
Higher load rating than 80% of Iowa bridges
179
Bridges in Webster · 41 in Poor condition
IA 175 38.6 t
Iowa average 30.9 t

Live comparison across Iowa.

Historical Sufficiency Rating

PlainBridge-computed
86.1 / 100 - historical 80–100 band
Structural adequacy /55
55.0
Serviceability /30
18.2
Essentiality /15
14.8
Special reductions
−2.0

FHWA discontinued this calculated item; it does not determine current condition, funding eligibility, posting, or closure. How the historical reference is calculated.

Condition Ratings

Deck
4/9
Poor (1–4)
Superstructure
6/9
Fair (5–6)
Substructure
6/9
Fair (5–6)
Inventory Load Rating
38.6 t
NBI inventory level (metric tons)
Overall Condition
Poor

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Structural Details

Year Built
1953
Material
Steel
Number of Spans
1
Structure Length
9.8 m (32 ft)
Deck Width
10.6 m (35 ft)
Owner
State Highway Agency
Avg Daily Traffic
960 vehicles/day
Structure Number
000000000052350

Condition Analysis

  • The deck (driving surface) rates poor at 4/9, advanced deterioration that should be prioritized for repair.
  • At 6/9, the superstructure (beams and supports above the deck) shows fair condition, with minor wear flagged for upkeep.
  • The substructure (piers and abutments) is in fair condition (6/9), with minor deterioration that may require routine maintenance.

How to read this record

IA 175 is in the federal Poor condition category. That is a component-based result, not a closure order.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Understand what Poor condition does and does not mean before drawing conclusions. Poor condition explained
  • Compare IA 175 against other structures in Webster and across Iowa. Iowa bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for IA 175?

IA 175 in Webster, Iowa has a deck rating of 4/9, superstructure rating of 6/9, and substructure rating of 6/9 on the FHWA's 0–9 scale.

How often is IA 175 inspected?

IA 175's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 960 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. IA 175 is currently shown as Poor condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for IA 175?

IA 175 has an NBI inventory load rating of 38.6 metric tons.

Who is responsible for maintaining IA 175?

IA 175 is owned and maintained by State Highway Agency.

How old is IA 175 and does age affect safety?

IA 175 was built in 1953, making it 73 years old.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Every figure on PlainBridge is rendered directly from federal source data, no number is typed in by an editor. This page draws directly on federal source data, no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error.