FHWA NBI 2024 Inspection record Public-domain dataset

G15 (130TH ST)

Carrying G15 (130TH ST) over NORTH TURKEY CREEK

2.6 mi west of hwy 25, Adair, Iowa

Data updated May 2026

FHWA NBI record, refreshed with each annual release.

Good
40 t Inventory load rating

Bridge Snapshot: G15 (130TH ST)

The G15 (130TH ST) bridge in Adair, Iowa carries G15 (130TH ST) over NORTH TURKEY CREEK. It was built in 2012, making it 14 years old today. The structure is built primarily of concrete continuous and spans 3 sections, stretching 22.3 meters (73 feet) end to end. Daily traffic averages 60 vehicles, placing it in the lower-traffic tier of Iowa bridges. It is owned and maintained by County Highway Agency.

The latest FHWA inspection records show a deck rating of 7/9, superstructure at 8/9, substructure at 8/9. The weakest component sits in good condition. No reported major component scores in the Poor range under the current federal condition thresholds. Its NBI inventory load rating is 39.9 metric tons.

Sourced from the FHWA National Bridge Inventory. See our methodology for refresh cadence and NBI release vintage.

How G15 (130TH ST) compares

▲ 9.0
Load rating vs Iowa average (30.9 t)
Top 18%
Higher load rating than 82% of Iowa bridges
208
Bridges in Adair · 26 in Poor condition
G15 (130TH ST) 39.9 t
Iowa average 30.9 t

Live comparison across Iowa.

Historical Sufficiency Rating

PlainBridge-computed
100.0 / 100 - historical 80–100 band
Structural adequacy /55
55.0
Serviceability /30
30.0
Essentiality /15
15.0
Special reductions
0

FHWA discontinued this calculated item; it does not determine current condition, funding eligibility, posting, or closure. How the historical reference is calculated.

Condition Ratings

Deck
7/9
Good (7–9)
Superstructure
8/9
Good (7–9)
Substructure
8/9
Good (7–9)
Inventory Load Rating
39.9 t
NBI inventory level (metric tons)
Overall Condition
Good

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Structural Details

Year Built
2012
Material
Concrete Continuous
Number of Spans
3
Structure Length
22.3 m (73 ft)
Deck Width
8.3 m (27 ft)
Owner
County Highway Agency
Avg Daily Traffic
60 vehicles/day
Structure Number
000000000058141

Condition Analysis

  • The deck (driving surface) is in good condition (7/9), showing no significant deterioration.
  • The superstructure (beams and supports above the deck) rates good at 8/9, with no significant deterioration on file.
  • At 8/9, the substructure (piers and abutments) is in good shape and shows no significant wear.

How to read this record

This page shows what the last federal inspection recorded, not whether G15 (130TH ST) is safe to cross today. Here is how to use it.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Learn how the 0–9 condition scale and Good/Fair/Poor categories are defined. How condition ratings work
  • Compare G15 (130TH ST) against other structures in Adair and across Iowa. Iowa bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for G15 (130TH ST)?

G15 (130TH ST) in Adair, Iowa has a deck rating of 7/9, superstructure rating of 8/9, and substructure rating of 8/9 on the FHWA's 0–9 scale.

How often is G15 (130TH ST) inspected?

G15 (130TH ST)'s responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 60 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. G15 (130TH ST) is currently shown as Good condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for G15 (130TH ST)?

G15 (130TH ST) has an NBI inventory load rating of 39.9 metric tons.

Who is responsible for maintaining G15 (130TH ST)?

G15 (130TH ST) is owned and maintained by County Highway Agency.

How old is G15 (130TH ST) and does age affect safety?

G15 (130TH ST) was built in 2012, making it 14 years old.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Every figure on PlainBridge is rendered directly from federal source data, no number is typed in by an editor. This page draws directly on federal source data, no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error.