FHWA NBI 2024 Inspection record Public-domain dataset

SH 122/Indepen Co.

Carrying SH 122/Indepen Co. over CARTER CREEK

2.0 MI S JCT SH 37 E, Independence, Arkansas

Data updated May 2026

FHWA NBI record, refreshed with each annual release.

Fair
19 t Inventory load rating

Bridge Snapshot: SH 122/Indepen Co.

The SH 122/Indepen Co. bridge in Independence, Arkansas carries SH 122/Indepen Co. over CARTER CREEK. It was built in 1955, making it 71 years old today. The structure is built primarily of concrete and spans 3 sections, stretching 16.8 meters (55 feet) end to end. Daily traffic averages 752 vehicles, placing it in the lower-traffic tier of Arkansas bridges. It is owned and maintained by State Highway Agency.

The latest FHWA inspection records show a deck rating of 7/9, superstructure at 6/9, substructure at 6/9. The weakest component sits in fair condition. All reported major components score above the Poor range. Its NBI inventory load rating is 19.1 metric tons.

Sourced from the FHWA National Bridge Inventory. See our methodology for refresh cadence and NBI release vintage.

How SH 122/Indepen Co. compares

▼ 5.8
Load rating vs Arkansas average (24.9 t)
Bottom 18%
Lower load rating than 82% of Arkansas bridges
92
Bridges in Independence · 6 in Poor condition
SH 122/Indepen Co. 19.1 t
Arkansas average 24.9 t

Live comparison across Arkansas.

Historical Sufficiency Rating

PlainBridge-computed
61.5 / 100 - historical 50–79.9 band
Structural adequacy /55
39.2
Serviceability /30
12.0
Essentiality /15
13.3
Special reductions
−3.0

FHWA discontinued this calculated item; it does not determine current condition, funding eligibility, posting, or closure. How the historical reference is calculated.

Condition Ratings

Deck
7/9
Good (7–9)
Superstructure
6/9
Fair (5–6)
Substructure
6/9
Fair (5–6)
Inventory Load Rating
19.1 t
NBI inventory level (metric tons)
Overall Condition
Fair

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Structural Details

Year Built
1955
Material
Concrete
Number of Spans
3
Structure Length
16.8 m (55 ft)
Deck Width
7.8 m (26 ft)
Owner
State Highway Agency
Avg Daily Traffic
752 vehicles/day
Structure Number
0000000000M1853

Condition Analysis

  • At 7/9, the deck (driving surface) is in good shape and shows no significant wear.
  • The superstructure (beams and supports above the deck) is in fair condition (6/9), with minor deterioration that may require routine maintenance.
  • The substructure (piers and abutments) rates fair at 6/9, minor deterioration that routine maintenance should address.

How to read this record

This page shows what the last federal inspection recorded, not whether SH 122/Indepen Co. is safe to cross today. Here is how to use it.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Learn how the 0–9 condition scale and Good/Fair/Poor categories are defined. How condition ratings work
  • Compare SH 122/Indepen Co. against other structures in Independence and across Arkansas. Arkansas bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for SH 122/Indepen Co.?

SH 122/Indepen Co. in Independence, Arkansas has a deck rating of 7/9, superstructure rating of 6/9, and substructure rating of 6/9 on the FHWA's 0–9 scale.

How often is SH 122/Indepen Co. inspected?

SH 122/Indepen Co.'s responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 752 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. SH 122/Indepen Co. is currently shown as Fair condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for SH 122/Indepen Co.?

SH 122/Indepen Co. has an NBI inventory load rating of 19.1 metric tons.

Who is responsible for maintaining SH 122/Indepen Co.?

SH 122/Indepen Co. is owned and maintained by State Highway Agency.

How old is SH 122/Indepen Co. and does age affect safety?

SH 122/Indepen Co. was built in 1955, making it 71 years old.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Every figure on PlainBridge is rendered directly from federal source data, no number is typed in by an editor. This page draws directly on federal source data, no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error.