FHWA NBI record, refreshed with each annual release.

Poor
49 t Inventory load rating

Bridge Snapshot: LANTERN AVE

The LANTERN AVE bridge in Clayton, Iowa carries LANTERN AVE over MINERS CREEK. It was built in 1912, making it 114 years old today. It was last reconstructed in 2005, extending its service life. The structure is built primarily of steel and spans 1 section, stretching 10.1 meters (33 feet) end to end. Daily traffic averages 11 vehicles, placing it in the lower-traffic tier of Iowa bridges. It is owned and maintained by County Highway Agency.

The latest FHWA inspection records show a deck rating of 7/9, superstructure at 7/9, substructure at 4/9. The weakest component sits in poor condition. Because at least one major component scores 4 or lower, this bridge falls in FHWA's Poor condition category. That category is not a closure order. Its NBI inventory load rating is 49.2 metric tons.

Sourced from the FHWA National Bridge Inventory. See our methodology for refresh cadence and NBI release vintage.

How LANTERN AVE compares

▲ 18.3
Load rating vs Iowa average (30.9 t)
Top 7%
Higher load rating than 93% of Iowa bridges
214
Bridges in Clayton · 21 in Poor condition
LANTERN AVE 49.2 t
Iowa average 30.9 t

Live comparison across Iowa.

Historical Sufficiency Rating

PlainBridge-computed
58.5 / 100 - historical 50–79.9 band
Structural adequacy /55
30.0
Serviceability /30
15.5
Essentiality /15
15.0
Special reductions
−2.0

FHWA discontinued this calculated item; it does not determine current condition, funding eligibility, posting, or closure. How the historical reference is calculated.

Condition Ratings

Deck
7/9
Good (7–9)
Superstructure
7/9
Good (7–9)
Substructure
4/9
Poor (1–4)
Inventory Load Rating
49.2 t
NBI inventory level (metric tons)
Overall Condition
Poor

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Structural Details

Year Built
1912
Last Reconstructed
2005
Material
Steel
Number of Spans
1
Structure Length
10.1 m (33 ft)
Deck Width
5.4 m (18 ft)
Owner
County Highway Agency
Avg Daily Traffic
11 vehicles/day
Structure Number
000000000118650

Condition Analysis

  • The deck (driving surface) rates good at 7/9, with no significant deterioration on file.
  • At 7/9, the superstructure (beams and supports above the deck) is in good shape and shows no significant wear.
  • At 4/9, the substructure (piers and abutments) is in poor shape, with advanced wear flagged for priority repair.

How to read this record

LANTERN AVE is in the federal Poor condition category. That is a component-based result, not a closure order.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Understand what Poor condition does and does not mean before drawing conclusions. Poor condition explained
  • Compare LANTERN AVE against other structures in Clayton and across Iowa. Iowa bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for LANTERN AVE?

LANTERN AVE in Clayton, Iowa has a deck rating of 7/9, superstructure rating of 7/9, and substructure rating of 4/9 on the FHWA's 0–9 scale.

How often is LANTERN AVE inspected?

LANTERN AVE's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 11 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. LANTERN AVE is currently shown as Poor condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for LANTERN AVE?

LANTERN AVE has an NBI inventory load rating of 49.2 metric tons.

Who is responsible for maintaining LANTERN AVE?

LANTERN AVE is owned and maintained by County Highway Agency.

How old is LANTERN AVE and does age affect safety?

LANTERN AVE was built in 1912, making it 114 years old and last reconstructed in 2005.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Every figure on PlainBridge is rendered directly from federal source data, no number is typed in by an editor. This page draws directly on federal source data, no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error.