Fair
37 t Inventory load rating

Bridge Snapshot: R AVE / P30

The R AVE / P30 bridge in Greene, Iowa carries R AVE / P30 over RACCOON RIVER. It was built in 1975, making it 51 years old today. The structure is built primarily of prestressed concrete and spans 4 sections, stretching 119.5 meters (392 feet) end to end. Daily traffic averages 190 vehicles, placing it in the lower-traffic tier of Iowa bridges. It is owned and maintained by County Highway Agency.

The latest FHWA inspection records show a deck rating of 6/9, superstructure at 6/9, substructure at 7/9. The weakest component sits in fair condition. None of this bridge's reported major components fall into the Poor condition range. Its NBI inventory load rating is 36.5 metric tons.

Sourced from the FHWA National Bridge Inventory. See our methodology for refresh cadence and NBI release vintage.

How R AVE / P30 compares

▲ 5.6
Load rating vs Iowa average (30.9 t)
Top 25%
Higher load rating than 75% of Iowa bridges
150
Bridges in Greene · 23 in Poor condition
R AVE / P30 36.5 t
Iowa average 30.9 t

Live comparison across Iowa.

Historical Sufficiency Rating

PlainBridge-computed
91.9 / 100 - historical 80–100 band
Structural adequacy /55
55.0
Serviceability /30
25.0
Essentiality /15
14.9
Special reductions
−3.0

FHWA discontinued this calculated item; it does not determine current condition, funding eligibility, posting, or closure. How the historical reference is calculated.

Condition Ratings

Deck
6/9
Fair (5–6)
Superstructure
6/9
Fair (5–6)
Substructure
7/9
Good (7–9)
Inventory Load Rating
36.5 t
NBI inventory level (metric tons)
Overall Condition
Fair

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Structural Details

Year Built
1975
Material
Prestressed Concrete
Number of Spans
4
Structure Length
119.5 m (392 ft)
Deck Width
10.4 m (34 ft)
Owner
County Highway Agency
Avg Daily Traffic
190 vehicles/day
Structure Number
000000000162195

Condition Analysis

  • The deck (driving surface) is in fair condition (6/9), with minor deterioration that may require routine maintenance.
  • The superstructure (beams and supports above the deck) is in fair condition (6/9), with minor deterioration that may require routine maintenance.
  • The substructure (piers and abutments) is in good condition (7/9), showing no significant deterioration.

How to read this record

This page shows what the last federal inspection recorded, not whether R AVE / P30 is safe to cross today. Here is how to use it.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Learn how the 0–9 condition scale and Good/Fair/Poor categories are defined. How condition ratings work
  • Compare R AVE / P30 against other structures in Greene and across Iowa. Iowa bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for R AVE / P30?

R AVE / P30 in Greene, Iowa has a deck rating of 6/9, superstructure rating of 6/9, and substructure rating of 7/9 on the FHWA's 0–9 scale.

How often is R AVE / P30 inspected?

R AVE / P30's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 190 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. R AVE / P30 is currently shown as Fair condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for R AVE / P30?

R AVE / P30 has an NBI inventory load rating of 36.5 metric tons.

Who is responsible for maintaining R AVE / P30?

R AVE / P30 is owned and maintained by County Highway Agency.

How old is R AVE / P30 and does age affect safety?

R AVE / P30 was built in 1975, making it 51 years old.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Every figure on PlainBridge is rendered directly from federal source data, no number is typed in by an editor. This page draws directly on federal source data, no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error.