FHWA NBI 2024 Inspection record Public-domain dataset

LOC 120TH ST

Carrying LOC 120TH ST over HINE CREEK

094293001, Kossuth, Iowa

Data updated May 2026

FHWA NBI record, refreshed with each annual release.

Good
45 t Inventory load rating

Bridge Snapshot: LOC 120TH ST

The LOC 120TH ST bridge in Kossuth, Iowa carries LOC 120TH ST over HINE CREEK. It was built in 1989, making it 37 years old today. The structure is built primarily of concrete continuous and spans 3 sections, stretching 24.4 meters (80 feet) end to end. Daily traffic averages 26 vehicles, placing it in the lower-traffic tier of Iowa bridges. It is owned and maintained by County Highway Agency.

The latest FHWA inspection records show a deck rating of 7/9, superstructure at 7/9, substructure at 7/9. The weakest component sits in good condition. No reported major component scores in the Poor range under the current federal condition thresholds. Its NBI inventory load rating is 45.4 metric tons.

Sourced from the FHWA National Bridge Inventory. See our methodology for refresh cadence and NBI release vintage.

How LOC 120TH ST compares

▲ 14.5
Load rating vs Iowa average (30.9 t)
Top 11%
Higher load rating than 89% of Iowa bridges
256
Bridges in Kossuth · 43 in Poor condition
LOC 120TH ST 45.4 t
Iowa average 30.9 t

Live comparison across Iowa.

Historical Sufficiency Rating

PlainBridge-computed
93.0 / 100 - historical 80–100 band
Structural adequacy /55
55.0
Serviceability /30
25.0
Essentiality /15
15.0
Special reductions
−2.0

FHWA discontinued this calculated item; it does not determine current condition, funding eligibility, posting, or closure. How the historical reference is calculated.

Condition Ratings

Deck
7/9
Good (7–9)
Superstructure
7/9
Good (7–9)
Substructure
7/9
Good (7–9)
Inventory Load Rating
45.4 t
NBI inventory level (metric tons)
Overall Condition
Good

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Structural Details

Year Built
1989
Material
Concrete Continuous
Number of Spans
3
Structure Length
24.4 m (80 ft)
Deck Width
8.2 m (27 ft)
Owner
County Highway Agency
Avg Daily Traffic
26 vehicles/day
Structure Number
000000000213951

Condition Analysis

  • The deck (driving surface) rates good at 7/9, with no significant deterioration on file.
  • At 7/9, the superstructure (beams and supports above the deck) is in good shape and shows no significant wear.
  • The substructure (piers and abutments) is in good condition (7/9), showing no significant deterioration.

How to read this record

This page shows what the last federal inspection recorded, not whether LOC 120TH ST is safe to cross today. Here is how to use it.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Learn how the 0–9 condition scale and Good/Fair/Poor categories are defined. How condition ratings work
  • Compare LOC 120TH ST against other structures in Kossuth and across Iowa. Iowa bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for LOC 120TH ST?

LOC 120TH ST in Kossuth, Iowa has a deck rating of 7/9, superstructure rating of 7/9, and substructure rating of 7/9 on the FHWA's 0–9 scale.

How often is LOC 120TH ST inspected?

LOC 120TH ST's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 26 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. LOC 120TH ST is currently shown as Good condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for LOC 120TH ST?

LOC 120TH ST has an NBI inventory load rating of 45.4 metric tons.

Who is responsible for maintaining LOC 120TH ST?

LOC 120TH ST is owned and maintained by County Highway Agency.

How old is LOC 120TH ST and does age affect safety?

LOC 120TH ST was built in 1989, making it 37 years old.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Every figure on PlainBridge is rendered directly from federal source data, no number is typed in by an editor. This page draws directly on federal source data, no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error.