FHWA NBI 2024 Inspection record Public-domain dataset

V21 (202ND ST)

Carrying V21 (202ND ST) over DEEP RIVER

078130508, Poweshiek, Iowa

Data updated May 2026

FHWA NBI record, refreshed with each annual release.

Good
32 t Inventory load rating

Bridge Snapshot: V21 (202ND ST)

The V21 (202ND ST) bridge in Poweshiek, Iowa carries V21 (202ND ST) over DEEP RIVER. It was built in 2013, making it 13 years old today. The structure is built primarily of prestressed concrete and spans 1 section, stretching 34.4 meters (113 feet) end to end. Daily traffic averages 80 vehicles, placing it in the lower-traffic tier of Iowa bridges. It is owned and maintained by County Highway Agency.

The latest FHWA inspection records show a deck rating of 8/9, superstructure at 8/9, substructure at 8/9. The weakest component sits in good condition. None of this bridge's reported major components fall into the Poor condition range. Its NBI inventory load rating is 32.4 metric tons.

Sourced from the FHWA National Bridge Inventory. See our methodology for refresh cadence and NBI release vintage.

How V21 (202ND ST) compares

▲ 1.5
Load rating vs Iowa average (30.9 t)
Top 48%
Higher load rating than 52% of Iowa bridges
221
Bridges in Poweshiek · 98 in Poor condition
V21 (202ND ST) 32.4 t
Iowa average 30.9 t

Live comparison across Iowa.

Historical Sufficiency Rating

PlainBridge-computed
98.0 / 100 - historical 80–100 band
Structural adequacy /55
55.0
Serviceability /30
30.0
Essentiality /15
15.0
Special reductions
−2.0

FHWA discontinued this calculated item; it does not determine current condition, funding eligibility, posting, or closure. How the historical reference is calculated.

Condition Ratings

Deck
8/9
Good (7–9)
Superstructure
8/9
Good (7–9)
Substructure
8/9
Good (7–9)
Inventory Load Rating
32.4 t
NBI inventory level (metric tons)
Overall Condition
Good

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Structural Details

Year Built
2013
Material
Prestressed Concrete
Number of Spans
1
Structure Length
34.4 m (113 ft)
Deck Width
10.1 m (33 ft)
Owner
County Highway Agency
Avg Daily Traffic
80 vehicles/day
Structure Number
000000000291211

Condition Analysis

  • The deck (driving surface) rates good at 8/9, with no significant deterioration on file.
  • At 8/9, the superstructure (beams and supports above the deck) is in good shape and shows no significant wear.
  • At 8/9, the substructure (piers and abutments) is in good shape and shows no significant wear.

How to read this record

This page shows what the last federal inspection recorded, not whether V21 (202ND ST) is safe to cross today. Here is how to use it.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Learn how the 0–9 condition scale and Good/Fair/Poor categories are defined. How condition ratings work
  • Compare V21 (202ND ST) against other structures in Poweshiek and across Iowa. Iowa bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for V21 (202ND ST)?

V21 (202ND ST) in Poweshiek, Iowa has a deck rating of 8/9, superstructure rating of 8/9, and substructure rating of 8/9 on the FHWA's 0–9 scale.

How often is V21 (202ND ST) inspected?

V21 (202ND ST)'s responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 80 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. V21 (202ND ST) is currently shown as Good condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for V21 (202ND ST)?

V21 (202ND ST) has an NBI inventory load rating of 32.4 metric tons.

Who is responsible for maintaining V21 (202ND ST)?

V21 (202ND ST) is owned and maintained by County Highway Agency.

How old is V21 (202ND ST) and does age affect safety?

V21 (202ND ST) was built in 2013, making it 13 years old.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Every figure on PlainBridge is rendered directly from federal source data, no number is typed in by an editor. This page draws directly on federal source data, no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error.