FHWA NBI 2024 Inspection record Public-domain dataset

FIELD ENT.

Carrying FIELD ENT. over DRAINAGE (SDB)

070390604, Page, Iowa

Data updated May 2026

FHWA NBI record, refreshed with each annual release.

Poor
18 t Inventory load rating

Bridge Snapshot: FIELD ENT.

The FIELD ENT. bridge in Page, Iowa carries FIELD ENT. over DRAINAGE (SDB). It was built in 1900, making it 126 years old today. The structure is built primarily of wood or timber and spans 1 section, stretching 7.0 meters (23 feet) end to end. Daily traffic averages 10 vehicles, placing it in the lower-traffic tier of Iowa bridges. It is owned and maintained by County Highway Agency.

The latest FHWA inspection records show a deck rating of 5/9, superstructure at 6/9, substructure at 4/9. The weakest component sits in poor condition. Because at least one major component scores 4 or lower, this bridge falls in FHWA's Poor condition category. That category is not a closure order. Its NBI inventory load rating is 17.7 metric tons.

Sourced from the FHWA National Bridge Inventory. See our methodology for refresh cadence and NBI release vintage.

How FIELD ENT. compares

▼ 13.2
Load rating vs Iowa average (30.9 t)
Bottom 14%
Lower load rating than 86% of Iowa bridges
185
Bridges in Page · 59 in Poor condition
FIELD ENT. 17.7 t
Iowa average 30.9 t

Live comparison across Iowa.

Historical Sufficiency Rating

PlainBridge-computed
45.5 / 100 - historical 20–49.9 band
Structural adequacy /55
11.7
Serviceability /30
19.0
Essentiality /15
14.8
Special reductions
0

FHWA discontinued this calculated item; it does not determine current condition, funding eligibility, posting, or closure. How the historical reference is calculated.

Condition Ratings

Deck
5/9
Fair (5–6)
Superstructure
6/9
Fair (5–6)
Substructure
4/9
Poor (1–4)
Inventory Load Rating
17.7 t
NBI inventory level (metric tons)
Overall Condition
Poor

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Structural Details

Year Built
1900
Material
Wood or Timber
Number of Spans
1
Structure Length
7.0 m (23 ft)
Deck Width
5.5 m (18 ft)
Owner
County Highway Agency
Avg Daily Traffic
10 vehicles/day
Structure Number
000000000363275

Condition Analysis

  • The deck (driving surface) rates fair at 5/9, minor deterioration that routine maintenance should address.
  • The superstructure (beams and supports above the deck) rates fair at 6/9, minor deterioration that routine maintenance should address.
  • The substructure (piers and abutments) rates poor at 4/9, advanced deterioration that should be prioritized for repair.

How to read this record

FIELD ENT. is in the federal Poor condition category. That is a component-based result, not a closure order.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Understand what Poor condition does and does not mean before drawing conclusions. Poor condition explained
  • Compare FIELD ENT. against other structures in Page and across Iowa. Iowa bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for FIELD ENT.?

FIELD ENT. in Page, Iowa has a deck rating of 5/9, superstructure rating of 6/9, and substructure rating of 4/9 on the FHWA's 0–9 scale.

How often is FIELD ENT. inspected?

FIELD ENT.'s responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 10 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. FIELD ENT. is currently shown as Poor condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for FIELD ENT.?

FIELD ENT. has an NBI inventory load rating of 17.7 metric tons.

Who is responsible for maintaining FIELD ENT.?

FIELD ENT. is owned and maintained by County Highway Agency.

How old is FIELD ENT. and does age affect safety?

FIELD ENT. was built in 1900, making it 126 years old.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Every figure on PlainBridge is rendered directly from federal source data, no number is typed in by an editor. This page draws directly on federal source data, no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error.