FHWA NBI 2024 Inspection record Public-domain dataset

MCCOLLISTER BLV

Carrying MCCOLLISTER BLV over IOWA RIVER

079062201, Johnson, Iowa

Data updated May 2026

FHWA NBI record, refreshed with each annual release.

Good
34 t Inventory load rating

Bridge Snapshot: MCCOLLISTER BLV

The MCCOLLISTER BLV bridge in Johnson, Iowa carries MCCOLLISTER BLV over IOWA RIVER. It was built in 2009, making it 17 years old today. The structure is built primarily of prestressed concrete and spans 3 sections, stretching 120.7 meters (396 feet) end to end. Daily traffic averages 6,000 vehicles, placing it in the moderately-trafficked tier of Iowa bridges. It is owned and maintained by City/Municipal Highway Agency.

The latest FHWA inspection records show a deck rating of 7/9, superstructure at 8/9, substructure at 7/9. The weakest component sits in good condition. All reported major components score above the Poor range. Its NBI inventory load rating is 34.3 metric tons.

Sourced from the FHWA National Bridge Inventory. See our methodology for refresh cadence and NBI release vintage.

How MCCOLLISTER BLV compares

▲ 3.4
Load rating vs Iowa average (30.9 t)
Top 30%
Higher load rating than 70% of Iowa bridges
317
Bridges in Johnson · 26 in Poor condition
MCCOLLISTER BLV 34.3 t
Iowa average 30.9 t

Live comparison across Iowa.

Historical Sufficiency Rating

PlainBridge-computed
97.4 / 100 - historical 80–100 band
Structural adequacy /55
55.0
Serviceability /30
28.0
Essentiality /15
14.4
Special reductions
0

FHWA discontinued this calculated item; it does not determine current condition, funding eligibility, posting, or closure. How the historical reference is calculated.

Condition Ratings

Deck
7/9
Good (7–9)
Superstructure
8/9
Good (7–9)
Substructure
7/9
Good (7–9)
Inventory Load Rating
34.3 t
NBI inventory level (metric tons)
Overall Condition
Good

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Structural Details

Year Built
2009
Material
Prestressed Concrete
Number of Spans
3
Structure Length
120.7 m (396 ft)
Deck Width
17.6 m (58 ft)
Owner
City/Municipal Highway Agency
Avg Daily Traffic
6,000 vehicles/day
Structure Number
000000000504890

Condition Analysis

  • The deck (driving surface) is in good condition (7/9), showing no significant deterioration.
  • At 8/9, the superstructure (beams and supports above the deck) is in good shape and shows no significant wear.
  • The substructure (piers and abutments) is in good condition (7/9), showing no significant deterioration.

How to read this record

This page shows what the last federal inspection recorded, not whether MCCOLLISTER BLV is safe to cross today. Here is how to use it.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Learn how the 0–9 condition scale and Good/Fair/Poor categories are defined. How condition ratings work
  • Compare MCCOLLISTER BLV against other structures in Johnson and across Iowa. Iowa bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for MCCOLLISTER BLV?

MCCOLLISTER BLV in Johnson, Iowa has a deck rating of 7/9, superstructure rating of 8/9, and substructure rating of 7/9 on the FHWA's 0–9 scale.

How often is MCCOLLISTER BLV inspected?

MCCOLLISTER BLV's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 6,000 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. MCCOLLISTER BLV is currently shown as Good condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for MCCOLLISTER BLV?

MCCOLLISTER BLV has an NBI inventory load rating of 34.3 metric tons.

Who is responsible for maintaining MCCOLLISTER BLV?

MCCOLLISTER BLV is owned and maintained by City/Municipal Highway Agency.

How old is MCCOLLISTER BLV and does age affect safety?

MCCOLLISTER BLV was built in 2009, making it 17 years old.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Every figure on PlainBridge is rendered directly from federal source data, no number is typed in by an editor. This page draws directly on federal source data, no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error.