FHWA NBI 2024 Inspection record Public-domain dataset

RTE 265

Carrying RTE 265 over POWER RESERVOIR

1.9 MI N JCT RTS 265 + 31, Niagara, New York

Data updated May 2026

FHWA NBI record, refreshed with each annual release.

Fair
58 t Inventory load rating

Bridge Snapshot: RTE 265

The RTE 265 bridge in Niagara, New York carries RTE 265 over POWER RESERVOIR. It was built in 1963, making it 63 years old today. It was last reconstructed in 2015, extending its service life. The structure is built primarily of steel continuous and spans 12 sections, stretching 249.3 meters (818 feet) end to end. Daily traffic averages 7,764 vehicles, placing it in the moderately-trafficked tier of New York bridges. It is owned and maintained by State Highway Agency.

The latest FHWA inspection records show a deck rating of 8/9, superstructure at 8/9, substructure at 6/9. The weakest component sits in fair condition. All reported major components score above the Poor range. Its NBI inventory load rating is 58.1 metric tons.

Sourced from the FHWA National Bridge Inventory. See our methodology for refresh cadence and NBI release vintage.

How RTE 265 compares

▲ 16.2
Load rating vs New York average (41.9 t)
Top 14%
Higher load rating than 86% of New York bridges
297
Bridges in Niagara · 18 in Poor condition
RTE 265 58.1 t
New York average 41.9 t

Live comparison across New York.

Historical Sufficiency Rating

PlainBridge-computed
96.9 / 100 - historical 80–100 band
Structural adequacy /55
55.0
Serviceability /30
28.0
Essentiality /15
13.9
Special reductions
0

FHWA discontinued this calculated item; it does not determine current condition, funding eligibility, posting, or closure. How the historical reference is calculated.

Condition Ratings

Deck
8/9
Good (7–9)
Superstructure
8/9
Good (7–9)
Substructure
6/9
Fair (5–6)
Inventory Load Rating
58.1 t
NBI inventory level (metric tons)
Overall Condition
Fair

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Structural Details

Year Built
1963
Last Reconstructed
2015
Material
Steel Continuous
Number of Spans
12
Structure Length
249.3 m (818 ft)
Deck Width
11.0 m (36 ft)
Owner
State Highway Agency
Avg Daily Traffic
7,764 vehicles/day
Structure Number
000000001043890

Condition Analysis

  • The deck (driving surface) rates good at 8/9, with no significant deterioration on file.
  • The superstructure (beams and supports above the deck) rates good at 8/9, with no significant deterioration on file.
  • The substructure (piers and abutments) rates fair at 6/9, minor deterioration that routine maintenance should address.

How to read this record

This page shows what the last federal inspection recorded, not whether RTE 265 is safe to cross today. Here is how to use it.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Learn how the 0–9 condition scale and Good/Fair/Poor categories are defined. How condition ratings work
  • Compare RTE 265 against other structures in Niagara and across New York. New York bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for RTE 265?

RTE 265 in Niagara, New York has a deck rating of 8/9, superstructure rating of 8/9, and substructure rating of 6/9 on the FHWA's 0–9 scale.

How often is RTE 265 inspected?

RTE 265's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 7,764 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. RTE 265 is currently shown as Fair condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for RTE 265?

RTE 265 has an NBI inventory load rating of 58.1 metric tons.

Who is responsible for maintaining RTE 265?

RTE 265 is owned and maintained by State Highway Agency.

How old is RTE 265 and does age affect safety?

RTE 265 was built in 1963, making it 63 years old and last reconstructed in 2015.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Every figure on PlainBridge is rendered directly from federal source data, no number is typed in by an editor. This page draws directly on federal source data, no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error.