FHWA NBI 2024 Inspection record Public-domain dataset

RTE 284

Carrying RTE 284 over RUTGERS CREEK

2.2 MI S JCT RTS 284+6, Orange, New York

Data updated May 2026

FHWA NBI record, refreshed with each annual release.

Poor
51 t Inventory load rating

Bridge Snapshot: RTE 284

The RTE 284 bridge in Orange, New York carries RTE 284 over RUTGERS CREEK. It was built in 1961, making it 65 years old today. It was last reconstructed in 1988, extending its service life. The structure is built primarily of steel and spans 2 sections, stretching 42.4 meters (139 feet) end to end. Daily traffic averages 3,886 vehicles, placing it in the moderately-trafficked tier of New York bridges. It is owned and maintained by State Highway Agency.

The latest FHWA inspection records show a deck rating of 7/9, superstructure at 5/9, substructure at 4/9. The weakest component sits in poor condition. At least one major component here scores 4 or below, which produces a Poor condition classification under FHWA's current reporting rules. Its NBI inventory load rating is 50.8 metric tons.

Sourced from the FHWA National Bridge Inventory. See our methodology for refresh cadence and NBI release vintage.

How RTE 284 compares

▲ 8.9
Load rating vs New York average (41.9 t)
Top 25%
Higher load rating than 75% of New York bridges
505
Bridges in Orange · 59 in Poor condition
RTE 284 50.8 t
New York average 41.9 t

Live comparison across New York.

Historical Sufficiency Rating

PlainBridge-computed
41.5 / 100 - historical 20–49.9 band
Structural adequacy /55
30.0
Serviceability /30
10.0
Essentiality /15
1.5
Special reductions
0

FHWA discontinued this calculated item; it does not determine current condition, funding eligibility, posting, or closure. How the historical reference is calculated.

Condition Ratings

Deck
7/9
Good (7–9)
Superstructure
5/9
Fair (5–6)
Substructure
4/9
Poor (1–4)
Inventory Load Rating
50.8 t
NBI inventory level (metric tons)
Overall Condition
Poor

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Structural Details

Year Built
1961
Last Reconstructed
1988
Material
Steel
Number of Spans
2
Structure Length
42.4 m (139 ft)
Deck Width
9.5 m (31 ft)
Owner
State Highway Agency
Avg Daily Traffic
3,886 vehicles/day
Structure Number
000000001044500

Condition Analysis

  • The deck (driving surface) rates good at 7/9, with no significant deterioration on file.
  • The superstructure (beams and supports above the deck) rates fair at 5/9, minor deterioration that routine maintenance should address.
  • At 4/9, the substructure (piers and abutments) is in poor shape, with advanced wear flagged for priority repair.

How to read this record

RTE 284 is in the federal Poor condition category. That is a component-based result, not a closure order.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Understand what Poor condition does and does not mean before drawing conclusions. Poor condition explained
  • Compare RTE 284 against other structures in Orange and across New York. New York bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for RTE 284?

RTE 284 in Orange, New York has a deck rating of 7/9, superstructure rating of 5/9, and substructure rating of 4/9 on the FHWA's 0–9 scale.

How often is RTE 284 inspected?

RTE 284's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 3,886 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. RTE 284 is currently shown as Poor condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for RTE 284?

RTE 284 has an NBI inventory load rating of 50.8 metric tons.

Who is responsible for maintaining RTE 284?

RTE 284 is owned and maintained by State Highway Agency.

How old is RTE 284 and does age affect safety?

RTE 284 was built in 1961, making it 65 years old and last reconstructed in 1988.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Every figure on PlainBridge is rendered directly from federal source data, no number is typed in by an editor. This page draws directly on federal source data, no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error.