FHWA NBI 2024 Inspection record Public-domain dataset

RTE I84

Carrying RTE I84 over MNRR PJ LINE

3.4 MI E JCT SH 17 & I84, Orange, New York

Data updated May 2026

FHWA NBI record, refreshed with each annual release.

Poor
49 t Inventory load rating

Bridge Snapshot: RTE I84

The RTE I84 bridge in Orange, New York carries RTE I84 over MNRR PJ LINE. It was built in 1969, making it 57 years old today. It was last reconstructed in 1996, extending its service life. The structure is built primarily of steel and spans 3 sections, stretching 68.0 meters (223 feet) end to end. Daily traffic averages 20,910 vehicles, placing it in the heavily-trafficked tier of New York bridges. It is owned and maintained by State Highway Agency.

The latest FHWA inspection records show a deck rating of 5/9, superstructure at 4/9, substructure at 4/9. The weakest component sits in poor condition. At least one major component here scores 4 or below, which produces a Poor condition classification under FHWA's current reporting rules. Its NBI inventory load rating is 49.0 metric tons.

Sourced from the FHWA National Bridge Inventory. See our methodology for refresh cadence and NBI release vintage.

How RTE I84 compares

▲ 7.1
Load rating vs New York average (41.9 t)
Top 28%
Higher load rating than 72% of New York bridges
505
Bridges in Orange · 59 in Poor condition
RTE I84 49.0 t
New York average 41.9 t

Live comparison across New York.

Historical Sufficiency Rating

PlainBridge-computed
67.5 / 100 - historical 50–79.9 band
Structural adequacy /55
30.0
Serviceability /30
26.0
Essentiality /15
11.5
Special reductions
0

FHWA discontinued this calculated item; it does not determine current condition, funding eligibility, posting, or closure. How the historical reference is calculated.

Condition Ratings

Deck
5/9
Fair (5–6)
Superstructure
4/9
Poor (1–4)
Substructure
4/9
Poor (1–4)
Inventory Load Rating
49.0 t
NBI inventory level (metric tons)
Overall Condition
Poor

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Structural Details

Year Built
1969
Last Reconstructed
1996
Material
Steel
Number of Spans
3
Structure Length
68.0 m (223 ft)
Deck Width
12.5 m (41 ft)
Owner
State Highway Agency
Avg Daily Traffic
20,910 vehicles/day
Structure Number
000000001052591

Condition Analysis

  • The deck (driving surface) rates fair at 5/9, minor deterioration that routine maintenance should address.
  • At 4/9, the superstructure (beams and supports above the deck) is in poor shape, with advanced wear flagged for priority repair.
  • The substructure (piers and abutments) is in poor condition (4/9), showing advanced deterioration that may require priority repair.

How to read this record

RTE I84 is in the federal Poor condition category. That is a component-based result, not a closure order.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Understand what Poor condition does and does not mean before drawing conclusions. Poor condition explained
  • Compare RTE I84 against other structures in Orange and across New York. New York bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for RTE I84?

RTE I84 in Orange, New York has a deck rating of 5/9, superstructure rating of 4/9, and substructure rating of 4/9 on the FHWA's 0–9 scale.

How often is RTE I84 inspected?

RTE I84's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 20,910 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. RTE I84 is currently shown as Poor condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for RTE I84?

RTE I84 has an NBI inventory load rating of 49.0 metric tons.

Who is responsible for maintaining RTE I84?

RTE I84 is owned and maintained by State Highway Agency.

How old is RTE I84 and does age affect safety?

RTE I84 was built in 1969, making it 57 years old and last reconstructed in 1996.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Every figure on PlainBridge is rendered directly from federal source data, no number is typed in by an editor. This page draws directly on federal source data, no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error.