FHWA NBI 2024 Inspection record Public-domain dataset

RTE I678

Carrying RTE I678 over RELIEF

JCT I495 & I678, Queens, New York

Data updated May 2026

FHWA NBI record, refreshed with each annual release.

Poor
30 t Inventory load rating

Bridge Snapshot: RTE I678

The RTE I678 bridge in Queens, New York carries RTE I678 over RELIEF. It was built in 1963, making it 63 years old today. The structure is built primarily of steel and spans 3 sections, stretching 117.3 meters (385 feet) end to end. Daily traffic averages 8,582 vehicles, placing it in the moderately-trafficked tier of New York bridges. It is owned and maintained by State Highway Agency.

The latest FHWA inspection records show a deck rating of 5/9, superstructure at 6/9, substructure at 4/9. The weakest component sits in poor condition. Because at least one major component scores 4 or lower, this bridge falls in FHWA's Poor condition category. That category is not a closure order. Its NBI inventory load rating is 29.9 metric tons.

Sourced from the FHWA National Bridge Inventory. See our methodology for refresh cadence and NBI release vintage.

How RTE I678 compares

▼ 12.0
Load rating vs New York average (41.9 t)
Bottom 22%
Lower load rating than 78% of New York bridges
755
Bridges in Queens · 5 in Poor condition
RTE I678 29.9 t
New York average 41.9 t

Live comparison across New York.

Historical Sufficiency Rating

PlainBridge-computed
68.1 / 100 - historical 50–79.9 band
Structural adequacy /55
28.7
Serviceability /30
27.0
Essentiality /15
12.4
Special reductions
0

FHWA discontinued this calculated item; it does not determine current condition, funding eligibility, posting, or closure. How the historical reference is calculated.

Condition Ratings

Deck
5/9
Fair (5–6)
Superstructure
6/9
Fair (5–6)
Substructure
4/9
Poor (1–4)
Inventory Load Rating
29.9 t
NBI inventory level (metric tons)
Overall Condition
Poor

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Structural Details

Year Built
1963
Material
Steel
Number of Spans
3
Structure Length
117.3 m (385 ft)
Deck Width
7.5 m (25 ft)
Owner
State Highway Agency
Avg Daily Traffic
8,582 vehicles/day
Structure Number
00000000105578I

Condition Analysis

  • At 5/9, the deck (driving surface) shows fair condition, with minor wear flagged for upkeep.
  • The superstructure (beams and supports above the deck) is in fair condition (6/9), with minor deterioration that may require routine maintenance.
  • At 4/9, the substructure (piers and abutments) is in poor shape, with advanced wear flagged for priority repair.

How to read this record

RTE I678 is in the federal Poor condition category. That is a component-based result, not a closure order.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Understand what Poor condition does and does not mean before drawing conclusions. Poor condition explained
  • Compare RTE I678 against other structures in Queens and across New York. New York bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for RTE I678?

RTE I678 in Queens, New York has a deck rating of 5/9, superstructure rating of 6/9, and substructure rating of 4/9 on the FHWA's 0–9 scale.

How often is RTE I678 inspected?

RTE I678's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 8,582 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. RTE I678 is currently shown as Poor condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for RTE I678?

RTE I678 has an NBI inventory load rating of 29.9 metric tons.

Who is responsible for maintaining RTE I678?

RTE I678 is owned and maintained by State Highway Agency.

How old is RTE I678 and does age affect safety?

RTE I678 was built in 1963, making it 63 years old.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Every figure on PlainBridge is rendered directly from federal source data, no number is typed in by an editor. This page draws directly on federal source data, no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error.