FHWA NBI 2024 Inspection record Public-domain dataset

SR1679

Carrying SR1679 over CULLASAJA RIVER

50 FT.W.JCT.US64, Macon, North Carolina

Data updated May 2026

FHWA NBI record, refreshed with each annual release.

Poor
22 t Inventory load rating

Bridge Snapshot: SR1679

The SR1679 bridge in Macon, North Carolina carries SR1679 over CULLASAJA RIVER. It was built in 1957, making it 69 years old today. It was last reconstructed in 1973, extending its service life. The structure is built primarily of steel and spans 2 sections, stretching 24.6 meters (81 feet) end to end. Daily traffic averages 70 vehicles, placing it in the lower-traffic tier of North Carolina bridges. It is owned and maintained by State Highway Agency.

The latest FHWA inspection records show a deck rating of 7/9, superstructure at 4/9, substructure at 5/9. The weakest component sits in poor condition. At least one major component here scores 4 or below, which produces a Poor condition classification under FHWA's current reporting rules. Its NBI inventory load rating is 21.7 metric tons.

Sourced from the FHWA National Bridge Inventory. See our methodology for refresh cadence and NBI release vintage.

How SR1679 compares

▼ 22.5
Load rating vs North Carolina average (44.2 t)
Bottom 9%
Lower load rating than 91% of North Carolina bridges
223
Bridges in Macon · 39 in Poor condition
SR1679 21.7 t
North Carolina average 44.2 t

Live comparison across North Carolina.

Historical Sufficiency Rating

PlainBridge-computed
58.5 / 100 - historical 50–79.9 band
Structural adequacy /55
18.6
Serviceability /30
28.0
Essentiality /15
14.9
Special reductions
−3.0

FHWA discontinued this calculated item; it does not determine current condition, funding eligibility, posting, or closure. How the historical reference is calculated.

Condition Ratings

Deck
7/9
Good (7–9)
Superstructure
4/9
Poor (1–4)
Substructure
5/9
Fair (5–6)
Inventory Load Rating
21.7 t
NBI inventory level (metric tons)
Overall Condition
Poor

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Structural Details

Year Built
1957
Last Reconstructed
1973
Material
Steel
Number of Spans
2
Structure Length
24.6 m (81 ft)
Deck Width
7.6 m (25 ft)
Owner
State Highway Agency
Avg Daily Traffic
70 vehicles/day
Structure Number
000000001130056

Condition Analysis

  • At 7/9, the deck (driving surface) is in good shape and shows no significant wear.
  • The superstructure (beams and supports above the deck) is in poor condition (4/9), showing advanced deterioration that may require priority repair.
  • At 5/9, the substructure (piers and abutments) shows fair condition, with minor wear flagged for upkeep.

How to read this record

SR1679 is in the federal Poor condition category. That is a component-based result, not a closure order.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Understand what Poor condition does and does not mean before drawing conclusions. Poor condition explained
  • Compare SR1679 against other structures in Macon and across North Carolina. North Carolina bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for SR1679?

SR1679 in Macon, North Carolina has a deck rating of 7/9, superstructure rating of 4/9, and substructure rating of 5/9 on the FHWA's 0–9 scale.

How often is SR1679 inspected?

SR1679's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 70 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. SR1679 is currently shown as Poor condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for SR1679?

SR1679 has an NBI inventory load rating of 21.7 metric tons.

Who is responsible for maintaining SR1679?

SR1679 is owned and maintained by State Highway Agency.

How old is SR1679 and does age affect safety?

SR1679 was built in 1957, making it 69 years old and last reconstructed in 1973.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Every figure on PlainBridge is rendered directly from federal source data, no number is typed in by an editor. This page draws directly on federal source data, no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error.