Good
33 t Inventory load rating

Bridge Snapshot: PORTER STREET

The PORTER STREET bridge in Bartow, Georgia carries PORTER STREET over CSX RAILROAD. It was built in 1978, making it 48 years old today. The structure is built primarily of steel and spans 3 sections, stretching 56.7 meters (186 feet) end to end. Daily traffic averages 6,840 vehicles, placing it in the moderately-trafficked tier of Georgia bridges. It is owned and maintained by City/Municipal Highway Agency.

The latest FHWA inspection records show a deck rating of 7/9, superstructure at 7/9, substructure at 7/9. The weakest component sits in good condition. No reported major component scores in the Poor range under the current federal condition thresholds. Its NBI inventory load rating is 32.6 metric tons.

Sourced from the FHWA National Bridge Inventory. See our methodology for refresh cadence and NBI release vintage.

How PORTER STREET compares

▼ 1.5
Load rating vs Georgia average (34.1 t)
Top 49%
Higher load rating than 51% of Georgia bridges
213
Bridges in Bartow · 4 in Poor condition
PORTER STREET 32.6 t
Georgia average 34.1 t

Live comparison across Georgia.

Historical Sufficiency Rating

PlainBridge-computed
75.7 / 100 - historical 50–79.9 band
Structural adequacy /55
55.0
Serviceability /30
10.0
Essentiality /15
13.7
Special reductions
−3.0

FHWA discontinued this calculated item; it does not determine current condition, funding eligibility, posting, or closure. How the historical reference is calculated.

Condition Ratings

Deck
7/9
Good (7–9)
Superstructure
7/9
Good (7–9)
Substructure
7/9
Good (7–9)
Inventory Load Rating
32.6 t
NBI inventory level (metric tons)
Overall Condition
Good

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Structural Details

Year Built
1978
Material
Steel
Number of Spans
3
Structure Length
56.7 m (186 ft)
Deck Width
11.2 m (37 ft)
Owner
City/Municipal Highway Agency
Avg Daily Traffic
6,840 vehicles/day
Structure Number
000000001550600

Condition Analysis

  • The deck (driving surface) rates good at 7/9, with no significant deterioration on file.
  • The superstructure (beams and supports above the deck) is in good condition (7/9), showing no significant deterioration.
  • The substructure (piers and abutments) rates good at 7/9, with no significant deterioration on file.

How to read this record

This page shows what the last federal inspection recorded, not whether PORTER STREET is safe to cross today. Here is how to use it.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Learn how the 0–9 condition scale and Good/Fair/Poor categories are defined. How condition ratings work
  • Compare PORTER STREET against other structures in Bartow and across Georgia. Georgia bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for PORTER STREET?

PORTER STREET in Bartow, Georgia has a deck rating of 7/9, superstructure rating of 7/9, and substructure rating of 7/9 on the FHWA's 0–9 scale.

How often is PORTER STREET inspected?

PORTER STREET's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 6,840 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. PORTER STREET is currently shown as Good condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for PORTER STREET?

PORTER STREET has an NBI inventory load rating of 32.6 metric tons.

Who is responsible for maintaining PORTER STREET?

PORTER STREET is owned and maintained by City/Municipal Highway Agency.

How old is PORTER STREET and does age affect safety?

PORTER STREET was built in 1978, making it 48 years old.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Every figure on PlainBridge is rendered directly from federal source data, no number is typed in by an editor. This page draws directly on federal source data, no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error.