FHWA NBI 2024 Inspection record Public-domain dataset

RTE 907V

Carrying RTE 907V over AMTRAK-W SIDE CON

4 MI NE ROUTE 9A+79 ST, New York, New York

Data updated May 2026

FHWA NBI record, refreshed with each annual release.

Poor
14 t Inventory load rating

Bridge Snapshot: RTE 907V

The RTE 907V bridge in New York, New York carries RTE 907V over AMTRAK-W SIDE CON. It was built in 1939, making it 87 years old today. It was last reconstructed in 1985, extending its service life. The structure is built primarily of steel and spans 26 sections, stretching 137.2 meters (450 feet) end to end. Daily traffic averages 105,892 vehicles, placing it in the heavily-trafficked tier of New York bridges. It is owned and maintained by City/Municipal Highway Agency.

The latest FHWA inspection records show a deck rating of 5/9, superstructure at 4/9, substructure at 6/9. The weakest component sits in poor condition. At least one major component here scores 4 or below, which produces a Poor condition classification under FHWA's current reporting rules. Its NBI inventory load rating is 13.6 metric tons.

Sourced from the FHWA National Bridge Inventory. See our methodology for refresh cadence and NBI release vintage.

How RTE 907V compares

▼ 28.3
Load rating vs New York average (41.9 t)
Bottom 3%
Lower load rating than 97% of New York bridges
299
Bridges in New York · 9 in Poor condition
RTE 907V 13.6 t
New York average 41.9 t

Live comparison across New York.

Historical Sufficiency Rating

PlainBridge-computed
16.7 / 100 - historical under-20 band
Structural adequacy /55
3.5
Serviceability /30
13.3
Essentiality /15
0.0
Special reductions
0

FHWA discontinued this calculated item; it does not determine current condition, funding eligibility, posting, or closure. How the historical reference is calculated.

Condition Ratings

Deck
5/9
Fair (5–6)
Superstructure
4/9
Poor (1–4)
Substructure
6/9
Fair (5–6)
Inventory Load Rating
13.6 t
NBI inventory level (metric tons)
Overall Condition
Poor

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Structural Details

Year Built
1939
Last Reconstructed
1985
Material
Steel
Number of Spans
26
Structure Length
137.2 m (450 ft)
Deck Width
7.3 m (24 ft)
Owner
City/Municipal Highway Agency
Avg Daily Traffic
105,892 vehicles/day
Structure Number
00000000222934A

Condition Analysis

  • The deck (driving surface) rates fair at 5/9, minor deterioration that routine maintenance should address.
  • The superstructure (beams and supports above the deck) rates poor at 4/9, advanced deterioration that should be prioritized for repair.
  • At 6/9, the substructure (piers and abutments) shows fair condition, with minor wear flagged for upkeep.

How to read this record

RTE 907V is in the federal Poor condition category. That is a component-based result, not a closure order.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Understand what Poor condition does and does not mean before drawing conclusions. Poor condition explained
  • Compare RTE 907V against other structures in New York and across New York. New York bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for RTE 907V?

RTE 907V in New York, New York has a deck rating of 5/9, superstructure rating of 4/9, and substructure rating of 6/9 on the FHWA's 0–9 scale.

How often is RTE 907V inspected?

RTE 907V's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 105,892 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. RTE 907V is currently shown as Poor condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for RTE 907V?

RTE 907V has an NBI inventory load rating of 13.6 metric tons.

Who is responsible for maintaining RTE 907V?

RTE 907V is owned and maintained by City/Municipal Highway Agency.

How old is RTE 907V and does age affect safety?

RTE 907V was built in 1939, making it 87 years old and last reconstructed in 1985.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Every figure on PlainBridge is rendered directly from federal source data, no number is typed in by an editor. This page draws directly on federal source data, no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error.