FHWA NBI 2024 Inspection record Public-domain dataset

E SENECA STREET

Carrying E SENECA STREET over CSX TRANSPRTATION

IN OSWEGO, Oswego, New York

Data updated May 2026

FHWA NBI record, refreshed with each annual release.

Fair
40 t Inventory load rating

Bridge Snapshot: E SENECA STREET

The E SENECA STREET bridge in Oswego, New York carries E SENECA STREET over CSX TRANSPRTATION. It was built in 1939, making it 87 years old today. It was last reconstructed in 1980, extending its service life. The structure is built primarily of prestressed concrete continuous and spans 4 sections, stretching 86.3 meters (283 feet) end to end. Daily traffic averages 2,536 vehicles, placing it in the moderately-trafficked tier of New York bridges. It is owned and maintained by City/Municipal Highway Agency.

The latest FHWA inspection records show a deck rating of 5/9, superstructure at 5/9, substructure at 6/9. The weakest component sits in fair condition. No reported major component scores in the Poor range under the current federal condition thresholds. Its NBI inventory load rating is 40.2 metric tons.

Sourced from the FHWA National Bridge Inventory. See our methodology for refresh cadence and NBI release vintage.

How E SENECA STREET compares

▼ 1.7
Load rating vs New York average (41.9 t)
Bottom 48%
Lower load rating than 52% of New York bridges
238
Bridges in Oswego · 23 in Poor condition
E SENECA STREET 40.2 t
New York average 41.9 t

Live comparison across New York.

Historical Sufficiency Rating

PlainBridge-computed
80.5 / 100 - historical 80–100 band
Structural adequacy /55
45.0
Serviceability /30
20.6
Essentiality /15
14.8
Special reductions
0

FHWA discontinued this calculated item; it does not determine current condition, funding eligibility, posting, or closure. How the historical reference is calculated.

Condition Ratings

Deck
5/9
Fair (5–6)
Superstructure
5/9
Fair (5–6)
Substructure
6/9
Fair (5–6)
Inventory Load Rating
40.2 t
NBI inventory level (metric tons)
Overall Condition
Fair

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Structural Details

Year Built
1939
Last Reconstructed
1980
Material
Prestressed Concrete Continuous
Number of Spans
4
Structure Length
86.3 m (283 ft)
Deck Width
12.8 m (42 ft)
Owner
City/Municipal Highway Agency
Avg Daily Traffic
2,536 vehicles/day
Structure Number
000000002256290

Condition Analysis

  • The deck (driving surface) rates fair at 5/9, minor deterioration that routine maintenance should address.
  • The superstructure (beams and supports above the deck) is in fair condition (5/9), with minor deterioration that may require routine maintenance.
  • The substructure (piers and abutments) is in fair condition (6/9), with minor deterioration that may require routine maintenance.

How to read this record

This page shows what the last federal inspection recorded, not whether E SENECA STREET is safe to cross today. Here is how to use it.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Learn how the 0–9 condition scale and Good/Fair/Poor categories are defined. How condition ratings work
  • Compare E SENECA STREET against other structures in Oswego and across New York. New York bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for E SENECA STREET?

E SENECA STREET in Oswego, New York has a deck rating of 5/9, superstructure rating of 5/9, and substructure rating of 6/9 on the FHWA's 0–9 scale.

How often is E SENECA STREET inspected?

E SENECA STREET's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 2,536 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. E SENECA STREET is currently shown as Fair condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for E SENECA STREET?

E SENECA STREET has an NBI inventory load rating of 40.2 metric tons.

Who is responsible for maintaining E SENECA STREET?

E SENECA STREET is owned and maintained by City/Municipal Highway Agency.

How old is E SENECA STREET and does age affect safety?

E SENECA STREET was built in 1939, making it 87 years old and last reconstructed in 1980.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Every figure on PlainBridge is rendered directly from federal source data, no number is typed in by an editor. This page draws directly on federal source data, no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error.