FHWA NBI 2024 Inspection record Public-domain dataset

RTE I90

Carrying RTE I90 over FALL BROOK

3.8 MI E 90I EXIT 43 RAMP, Ontario, New York

Data updated May 2026

FHWA NBI record, refreshed with each annual release.

Poor
20 t Inventory load rating

Bridge Snapshot: RTE I90

The RTE I90 bridge in Ontario, New York carries RTE I90 over FALL BROOK. It was built in 1954, making it 72 years old today. The structure is built primarily of steel and spans 1 section, stretching 15.5 meters (51 feet) end to end. Daily traffic averages 18,296 vehicles, placing it in the heavily-trafficked tier of New York bridges. It is owned and maintained by State Toll Authority.

The latest FHWA inspection records show a deck rating of 4/9, superstructure at 5/9, substructure at 5/9. The weakest component sits in poor condition. Because at least one major component scores 4 or lower, this bridge falls in FHWA's Poor condition category. That category is not a closure order. Its NBI inventory load rating is 19.8 metric tons.

Sourced from the FHWA National Bridge Inventory. See our methodology for refresh cadence and NBI release vintage.

How RTE I90 compares

▼ 22.1
Load rating vs New York average (41.9 t)
Bottom 8%
Lower load rating than 92% of New York bridges
187
Bridges in Ontario · 11 in Poor condition
RTE I90 19.8 t
New York average 41.9 t

Live comparison across New York.

Historical Sufficiency Rating

PlainBridge-computed
56.4 / 100 - historical 50–79.9 band
Structural adequacy /55
30.4
Serviceability /30
26.0
Essentiality /15
0.0
Special reductions
0

FHWA discontinued this calculated item; it does not determine current condition, funding eligibility, posting, or closure. How the historical reference is calculated.

Condition Ratings

Deck
4/9
Poor (1–4)
Superstructure
5/9
Fair (5–6)
Substructure
5/9
Fair (5–6)
Inventory Load Rating
19.8 t
NBI inventory level (metric tons)
Overall Condition
Poor

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Structural Details

Year Built
1954
Material
Steel
Number of Spans
1
Structure Length
15.5 m (51 ft)
Deck Width
17.1 m (56 ft)
Owner
State Toll Authority
Avg Daily Traffic
18,296 vehicles/day
Structure Number
000000005510812

Condition Analysis

  • The deck (driving surface) rates poor at 4/9, advanced deterioration that should be prioritized for repair.
  • The superstructure (beams and supports above the deck) rates fair at 5/9, minor deterioration that routine maintenance should address.
  • The substructure (piers and abutments) rates fair at 5/9, minor deterioration that routine maintenance should address.

How to read this record

RTE I90 is in the federal Poor condition category. That is a component-based result, not a closure order.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Understand what Poor condition does and does not mean before drawing conclusions. Poor condition explained
  • Compare RTE I90 against other structures in Ontario and across New York. New York bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for RTE I90?

RTE I90 in Ontario, New York has a deck rating of 4/9, superstructure rating of 5/9, and substructure rating of 5/9 on the FHWA's 0–9 scale.

How often is RTE I90 inspected?

RTE I90's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 18,296 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. RTE I90 is currently shown as Poor condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for RTE I90?

RTE I90 has an NBI inventory load rating of 19.8 metric tons.

Who is responsible for maintaining RTE I90?

RTE I90 is owned and maintained by State Toll Authority.

How old is RTE I90 and does age affect safety?

RTE I90 was built in 1954, making it 72 years old.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Every figure on PlainBridge is rendered directly from federal source data, no number is typed in by an editor. This page draws directly on federal source data, no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error.