FHWA NBI 2024 Inspection record Public-domain dataset

GEORGE DEEN ROAD

Carrying GEORGE DEEN ROAD over BROXTON CREEK

2.6 MI E OF BROXTON, Coffee, Georgia

Data updated May 2026

FHWA NBI record, refreshed with each annual release.

Good
30 t Inventory load rating

Bridge Snapshot: GEORGE DEEN ROAD

The GEORGE DEEN ROAD bridge in Coffee, Georgia carries GEORGE DEEN ROAD over BROXTON CREEK. It was built in 1954, making it 72 years old today. It was last reconstructed in 2000, extending its service life. The structure is built primarily of prestressed concrete and spans 6 sections, stretching 28.0 meters (92 feet) end to end. Daily traffic averages 490 vehicles, placing it in the lower-traffic tier of Georgia bridges. It is owned and maintained by County Highway Agency.

The latest FHWA inspection records show a deck rating of 7/9, superstructure at 7/9, substructure at 7/9. The weakest component sits in good condition. None of this bridge's reported major components fall into the Poor condition range. Its NBI inventory load rating is 29.9 metric tons.

Sourced from the FHWA National Bridge Inventory. See our methodology for refresh cadence and NBI release vintage.

How GEORGE DEEN ROAD compares

▼ 4.2
Load rating vs Georgia average (34.1 t)
Bottom 46%
Lower load rating than 54% of Georgia bridges
126
Bridges in Coffee · 1 in Poor condition
GEORGE DEEN ROAD 29.9 t
Georgia average 34.1 t

Live comparison across Georgia.

Historical Sufficiency Rating

PlainBridge-computed
82.0 / 100 - historical 80–100 band
Structural adequacy /55
53.7
Serviceability /30
15.5
Essentiality /15
14.8
Special reductions
−2.0

FHWA discontinued this calculated item; it does not determine current condition, funding eligibility, posting, or closure. How the historical reference is calculated.

Condition Ratings

Deck
7/9
Good (7–9)
Superstructure
7/9
Good (7–9)
Substructure
7/9
Good (7–9)
Inventory Load Rating
29.9 t
NBI inventory level (metric tons)
Overall Condition
Good

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Structural Details

Year Built
1954
Last Reconstructed
2000
Material
Prestressed Concrete
Number of Spans
6
Structure Length
28.0 m (92 ft)
Deck Width
7.7 m (25 ft)
Owner
County Highway Agency
Avg Daily Traffic
490 vehicles/day
Structure Number
000000006950100

Condition Analysis

  • At 7/9, the deck (driving surface) is in good shape and shows no significant wear.
  • At 7/9, the superstructure (beams and supports above the deck) is in good shape and shows no significant wear.
  • The substructure (piers and abutments) rates good at 7/9, with no significant deterioration on file.

How to read this record

This page shows what the last federal inspection recorded, not whether GEORGE DEEN ROAD is safe to cross today. Here is how to use it.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Learn how the 0–9 condition scale and Good/Fair/Poor categories are defined. How condition ratings work
  • Compare GEORGE DEEN ROAD against other structures in Coffee and across Georgia. Georgia bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for GEORGE DEEN ROAD?

GEORGE DEEN ROAD in Coffee, Georgia has a deck rating of 7/9, superstructure rating of 7/9, and substructure rating of 7/9 on the FHWA's 0–9 scale.

How often is GEORGE DEEN ROAD inspected?

GEORGE DEEN ROAD's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 490 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. GEORGE DEEN ROAD is currently shown as Good condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for GEORGE DEEN ROAD?

GEORGE DEEN ROAD has an NBI inventory load rating of 29.9 metric tons.

Who is responsible for maintaining GEORGE DEEN ROAD?

GEORGE DEEN ROAD is owned and maintained by County Highway Agency.

How old is GEORGE DEEN ROAD and does age affect safety?

GEORGE DEEN ROAD was built in 1954, making it 72 years old and last reconstructed in 2000.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Every figure on PlainBridge is rendered directly from federal source data, no number is typed in by an editor. This page draws directly on federal source data, no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error.