FHWA NBI 2024 Inspection record Public-domain dataset

SE NEWNAN BYPASS

Carrying SE NEWNAN BYPASS over NOR/SOU. RAILROAD

2.5 MI E OF NEWNAN, Coweta, Georgia

Data updated May 2026

FHWA NBI record, refreshed with each annual release.

Good
44 t Inventory load rating

Bridge Snapshot: SE NEWNAN BYPASS

The SE NEWNAN BYPASS bridge in Coweta, Georgia carries SE NEWNAN BYPASS over NOR/SOU. RAILROAD. It was built in 2016, making it 10 years old today. The structure is built primarily of prestressed concrete and spans 1 section, stretching 36.9 meters (121 feet) end to end. Daily traffic averages 9,181 vehicles, placing it in the moderately-trafficked tier of Georgia bridges. It is owned and maintained by County Highway Agency.

The latest FHWA inspection records show a deck rating of 7/9, superstructure at 8/9, substructure at 8/9. The weakest component sits in good condition. All reported major components score above the Poor range. Its NBI inventory load rating is 44.4 metric tons.

Sourced from the FHWA National Bridge Inventory. See our methodology for refresh cadence and NBI release vintage.

How SE NEWNAN BYPASS compares

▲ 10.3
Load rating vs Georgia average (34.1 t)
Top 13%
Higher load rating than 87% of Georgia bridges
166
Bridges in Coweta · 1 in Poor condition
SE NEWNAN BYPASS 44.4 t
Georgia average 34.1 t

Live comparison across Georgia.

Historical Sufficiency Rating

PlainBridge-computed
96.6 / 100 - historical 80–100 band
Structural adequacy /55
55.0
Serviceability /30
30.0
Essentiality /15
11.6
Special reductions
0

FHWA discontinued this calculated item; it does not determine current condition, funding eligibility, posting, or closure. How the historical reference is calculated.

Condition Ratings

Deck
7/9
Good (7–9)
Superstructure
8/9
Good (7–9)
Substructure
8/9
Good (7–9)
Inventory Load Rating
44.4 t
NBI inventory level (metric tons)
Overall Condition
Good

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Structural Details

Year Built
2016
Material
Prestressed Concrete
Number of Spans
1
Structure Length
36.9 m (121 ft)
Deck Width
12.2 m (40 ft)
Owner
County Highway Agency
Avg Daily Traffic
9,181 vehicles/day
Structure Number
000000007751740

Condition Analysis

  • The deck (driving surface) rates good at 7/9, with no significant deterioration on file.
  • The superstructure (beams and supports above the deck) rates good at 8/9, with no significant deterioration on file.
  • At 8/9, the substructure (piers and abutments) is in good shape and shows no significant wear.

How to read this record

This page shows what the last federal inspection recorded, not whether SE NEWNAN BYPASS is safe to cross today. Here is how to use it.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Learn how the 0–9 condition scale and Good/Fair/Poor categories are defined. How condition ratings work
  • Compare SE NEWNAN BYPASS against other structures in Coweta and across Georgia. Georgia bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for SE NEWNAN BYPASS?

SE NEWNAN BYPASS in Coweta, Georgia has a deck rating of 7/9, superstructure rating of 8/9, and substructure rating of 8/9 on the FHWA's 0–9 scale.

How often is SE NEWNAN BYPASS inspected?

SE NEWNAN BYPASS's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 9,181 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. SE NEWNAN BYPASS is currently shown as Good condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for SE NEWNAN BYPASS?

SE NEWNAN BYPASS has an NBI inventory load rating of 44.4 metric tons.

Who is responsible for maintaining SE NEWNAN BYPASS?

SE NEWNAN BYPASS is owned and maintained by County Highway Agency.

How old is SE NEWNAN BYPASS and does age affect safety?

SE NEWNAN BYPASS was built in 2016, making it 10 years old.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Every figure on PlainBridge is rendered directly from federal source data, no number is typed in by an editor. This page draws directly on federal source data, no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error.