FHWA NBI 2024 Inspection record Public-domain dataset

E MAIN ST,FAS 6488

Carrying E MAIN ST,FAS 6488 over BEAVER CK

0.4E BUFFALO GAP, Custer, South Dakota

Data updated May 2026

FHWA NBI record, refreshed with each annual release.

Poor
10 t Inventory load rating

Bridge Snapshot: E MAIN ST,FAS 6488

The E MAIN ST,FAS 6488 bridge in Custer, South Dakota carries E MAIN ST,FAS 6488 over BEAVER CK. It was built in 1971, making it 55 years old today. The structure is built primarily of prestressed concrete and spans 1 section, stretching 11.3 meters (37 feet) end to end. Daily traffic averages 108 vehicles, placing it in the lower-traffic tier of South Dakota bridges. It is owned and maintained by County Highway Agency.

The latest FHWA inspection records show a deck rating of 5/9, superstructure at 7/9, substructure at 3/9. The weakest component sits in poor condition. Because at least one major component scores 4 or lower, this bridge falls in FHWA's Poor condition category. That category is not a closure order. Its NBI inventory load rating is 9.5 metric tons.

Sourced from the FHWA National Bridge Inventory. See our methodology for refresh cadence and NBI release vintage.

How E MAIN ST,FAS 6488 compares

▼ 23.0
Load rating vs South Dakota average (32.5 t)
Bottom 5%
Lower load rating than 95% of South Dakota bridges
95
Bridges in Custer · 5 in Poor condition
E MAIN ST,FAS 6488 9.5 t
South Dakota average 32.5 t

Live comparison across South Dakota.

Historical Sufficiency Rating

PlainBridge-computed
38.9 / 100 - historical 20–49.9 band
Structural adequacy /55
0.0
Serviceability /30
24.0
Essentiality /15
14.9
Special reductions
0

FHWA discontinued this calculated item; it does not determine current condition, funding eligibility, posting, or closure. How the historical reference is calculated.

Condition Ratings

Deck
5/9
Fair (5–6)
Superstructure
7/9
Good (7–9)
Substructure
3/9
Poor (1–4)
Inventory Load Rating
9.5 t
NBI inventory level (metric tons)
Overall Condition
Poor

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Structural Details

Year Built
1971
Material
Prestressed Concrete
Number of Spans
1
Structure Length
11.3 m (37 ft)
Deck Width
8.2 m (27 ft)
Owner
County Highway Agency
Avg Daily Traffic
108 vehicles/day
Structure Number
000000017379260

Condition Analysis

  • The deck (driving surface) rates fair at 5/9, minor deterioration that routine maintenance should address.
  • At 7/9, the superstructure (beams and supports above the deck) is in good shape and shows no significant wear.
  • The substructure (piers and abutments) rates poor at 3/9, advanced deterioration that should be prioritized for repair.

How to read this record

E MAIN ST,FAS 6488 is in the federal Poor condition category. That is a component-based result, not a closure order.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Understand what Poor condition does and does not mean before drawing conclusions. Poor condition explained
  • Compare E MAIN ST,FAS 6488 against other structures in Custer and across South Dakota. South Dakota bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for E MAIN ST,FAS 6488?

E MAIN ST,FAS 6488 in Custer, South Dakota has a deck rating of 5/9, superstructure rating of 7/9, and substructure rating of 3/9 on the FHWA's 0–9 scale.

How often is E MAIN ST,FAS 6488 inspected?

E MAIN ST,FAS 6488's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 108 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. E MAIN ST,FAS 6488 is currently shown as Poor condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for E MAIN ST,FAS 6488?

E MAIN ST,FAS 6488 has an NBI inventory load rating of 9.5 metric tons.

Who is responsible for maintaining E MAIN ST,FAS 6488?

E MAIN ST,FAS 6488 is owned and maintained by County Highway Agency.

How old is E MAIN ST,FAS 6488 and does age affect safety?

E MAIN ST,FAS 6488 was built in 1971, making it 55 years old.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Every figure on PlainBridge is rendered directly from federal source data, no number is typed in by an editor. This page draws directly on federal source data, no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error.