FHWA NBI 2024 Inspection record Public-domain dataset

GORDON STREET

Carrying GORDON STREET over NS RAILROAD (719083G)

IN DALTON, Whitfield, Georgia

Data updated May 2026

FHWA NBI record, refreshed with each annual release.

Good
14 t Inventory load rating

Bridge Snapshot: GORDON STREET

The GORDON STREET bridge in Whitfield, Georgia carries GORDON STREET over NS RAILROAD (719083G). It was built in 1937, making it 89 years old today. The structure is built primarily of steel and spans 6 sections, stretching 63.1 meters (207 feet) end to end. Daily traffic averages 900 vehicles, placing it in the lower-traffic tier of Georgia bridges. It is owned and maintained by City/Municipal Highway Agency.

The latest FHWA inspection records show a deck rating of 7/9, superstructure at 7/9, substructure at 7/9. The weakest component sits in good condition. No reported major component scores in the Poor range under the current federal condition thresholds. Its NBI inventory load rating is 13.6 metric tons.

Sourced from the FHWA National Bridge Inventory. See our methodology for refresh cadence and NBI release vintage.

How GORDON STREET compares

▼ 20.5
Load rating vs Georgia average (34.1 t)
Bottom 3%
Lower load rating than 97% of Georgia bridges
131
Bridges in Whitfield · 2 in Poor condition
GORDON STREET 13.6 t
Georgia average 34.1 t

Live comparison across Georgia.

Historical Sufficiency Rating

PlainBridge-computed
49.2 / 100 - historical 20–49.9 band
Structural adequacy /55
28.5
Serviceability /30
9.0
Essentiality /15
14.7
Special reductions
−3.0

FHWA discontinued this calculated item; it does not determine current condition, funding eligibility, posting, or closure. How the historical reference is calculated.

Condition Ratings

Deck
7/9
Good (7–9)
Superstructure
7/9
Good (7–9)
Substructure
7/9
Good (7–9)
Inventory Load Rating
13.6 t
NBI inventory level (metric tons)
Overall Condition
Good

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Structural Details

Year Built
1937
Material
Steel
Number of Spans
6
Structure Length
63.1 m (207 ft)
Deck Width
10.8 m (35 ft)
Owner
City/Municipal Highway Agency
Avg Daily Traffic
900 vehicles/day
Structure Number
000000031300630

Condition Analysis

  • The deck (driving surface) is in good condition (7/9), showing no significant deterioration.
  • At 7/9, the superstructure (beams and supports above the deck) is in good shape and shows no significant wear.
  • At 7/9, the substructure (piers and abutments) is in good shape and shows no significant wear.

How to read this record

This page shows what the last federal inspection recorded, not whether GORDON STREET is safe to cross today. Here is how to use it.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Learn how the 0–9 condition scale and Good/Fair/Poor categories are defined. How condition ratings work
  • Compare GORDON STREET against other structures in Whitfield and across Georgia. Georgia bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for GORDON STREET?

GORDON STREET in Whitfield, Georgia has a deck rating of 7/9, superstructure rating of 7/9, and substructure rating of 7/9 on the FHWA's 0–9 scale.

How often is GORDON STREET inspected?

GORDON STREET's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 900 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. GORDON STREET is currently shown as Good condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for GORDON STREET?

GORDON STREET has an NBI inventory load rating of 13.6 metric tons.

Who is responsible for maintaining GORDON STREET?

GORDON STREET is owned and maintained by City/Municipal Highway Agency.

How old is GORDON STREET and does age affect safety?

GORDON STREET was built in 1937, making it 89 years old.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Every figure on PlainBridge is rendered directly from federal source data, no number is typed in by an editor. This page draws directly on federal source data, no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error.