FHWA NBI 2024 Inspection record Public-domain dataset

47840 300TH ST

Carrying 47840 300TH ST over DRAINAGE DITCH

1N & 0.6W ALCESTER, Union, South Dakota

Data updated May 2026

FHWA NBI record, refreshed with each annual release.

Poor
12 t Inventory load rating

Bridge Snapshot: 47840 300TH ST

The 47840 300TH ST bridge in Union, South Dakota carries 47840 300TH ST over DRAINAGE DITCH. It was built in 1997, making it 29 years old today. The structure is built primarily of steel and spans 2 sections, stretching 10.1 meters (33 feet) end to end. Daily traffic averages 40 vehicles, placing it in the lower-traffic tier of South Dakota bridges. It is owned and maintained by County Highway Agency.

The latest FHWA inspection records show a deck rating of 4/9, superstructure at 5/9, substructure at 3/9. The weakest component sits in poor condition. At least one major component here scores 4 or below, which produces a Poor condition classification under FHWA's current reporting rules. Its NBI inventory load rating is 12.2 metric tons.

Sourced from the FHWA National Bridge Inventory. See our methodology for refresh cadence and NBI release vintage.

How 47840 300TH ST compares

▼ 20.3
Load rating vs South Dakota average (32.5 t)
Bottom 7%
Lower load rating than 93% of South Dakota bridges
172
Bridges in Union · 32 in Poor condition
47840 300TH ST 12.2 t
South Dakota average 32.5 t

Live comparison across South Dakota.

Historical Sufficiency Rating

PlainBridge-computed
38.0 / 100 - historical 20–49.9 band
Structural adequacy /55
0.0
Serviceability /30
23.0
Essentiality /15
15.0
Special reductions
0

FHWA discontinued this calculated item; it does not determine current condition, funding eligibility, posting, or closure. How the historical reference is calculated.

Condition Ratings

Deck
4/9
Poor (1–4)
Superstructure
5/9
Fair (5–6)
Substructure
3/9
Poor (1–4)
Inventory Load Rating
12.2 t
NBI inventory level (metric tons)
Overall Condition
Poor

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Structural Details

Year Built
1997
Material
Steel
Number of Spans
2
Structure Length
10.1 m (33 ft)
Deck Width
8.5 m (28 ft)
Owner
County Highway Agency
Avg Daily Traffic
40 vehicles/day
Structure Number
000000064084030

Condition Analysis

  • At 4/9, the deck (driving surface) is in poor shape, with advanced wear flagged for priority repair.
  • At 5/9, the superstructure (beams and supports above the deck) shows fair condition, with minor wear flagged for upkeep.
  • The substructure (piers and abutments) rates poor at 3/9, advanced deterioration that should be prioritized for repair.

How to read this record

47840 300TH ST is in the federal Poor condition category. That is a component-based result, not a closure order.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Understand what Poor condition does and does not mean before drawing conclusions. Poor condition explained
  • Compare 47840 300TH ST against other structures in Union and across South Dakota. South Dakota bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for 47840 300TH ST?

47840 300TH ST in Union, South Dakota has a deck rating of 4/9, superstructure rating of 5/9, and substructure rating of 3/9 on the FHWA's 0–9 scale.

How often is 47840 300TH ST inspected?

47840 300TH ST's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 40 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. 47840 300TH ST is currently shown as Poor condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for 47840 300TH ST?

47840 300TH ST has an NBI inventory load rating of 12.2 metric tons.

Who is responsible for maintaining 47840 300TH ST?

47840 300TH ST is owned and maintained by County Highway Agency.

How old is 47840 300TH ST and does age affect safety?

47840 300TH ST was built in 1997, making it 29 years old.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Every figure on PlainBridge is rendered directly from federal source data, no number is typed in by an editor. This page draws directly on federal source data, no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error.