FHWA NBI 2024 Inspection record Public-domain dataset

IL 40 FAP 646

Carrying IL 40 FAP 646 over BN RR

SOUTH EDGE OF BUDA, Bureau, Illinois

Data updated May 2026

FHWA NBI record, refreshed with each annual release.

Poor
41 t Inventory load rating

Bridge Snapshot: IL 40 FAP 646

The IL 40 FAP 646 bridge in Bureau, Illinois carries IL 40 FAP 646 over BN RR. It was built in 1982, making it 44 years old today. The structure is built primarily of steel continuous and spans 3 sections, stretching 72.8 meters (239 feet) end to end. Daily traffic averages 1,100 vehicles, placing it in the moderately-trafficked tier of Illinois bridges. It is owned and maintained by State Highway Agency.

The latest FHWA inspection records show a deck rating of 4/9, superstructure at 6/9, substructure at 7/9. The weakest component sits in poor condition. A component scored 4 or below, placing this bridge in the federal Poor condition category rather than declaring it unsafe or closed. Its NBI inventory load rating is 41.1 metric tons.

Sourced from the FHWA National Bridge Inventory. See our methodology for refresh cadence and NBI release vintage.

How IL 40 FAP 646 compares

▲ 6.5
Load rating vs Illinois average (34.6 t)
Top 17%
Higher load rating than 83% of Illinois bridges
382
Bridges in Bureau · 51 in Poor condition
IL 40 FAP 646 41.1 t
Illinois average 34.6 t

Live comparison across Illinois.

Historical Sufficiency Rating

PlainBridge-computed
92.6 / 100 - historical 80–100 band
Structural adequacy /55
55.0
Serviceability /30
26.0
Essentiality /15
11.7
Special reductions
−0.1

FHWA discontinued this calculated item; it does not determine current condition, funding eligibility, posting, or closure. How the historical reference is calculated.

Condition Ratings

Deck
4/9
Poor (1–4)
Superstructure
6/9
Fair (5–6)
Substructure
7/9
Good (7–9)
Inventory Load Rating
41.1 t
NBI inventory level (metric tons)
Overall Condition
Poor

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Structural Details

Year Built
1982
Material
Steel Continuous
Number of Spans
3
Structure Length
72.8 m (239 ft)
Deck Width
10.7 m (35 ft)
Owner
State Highway Agency
Avg Daily Traffic
1,100 vehicles/day
Structure Number
006013800000000

Condition Analysis

  • At 4/9, the deck (driving surface) is in poor shape, with advanced wear flagged for priority repair.
  • At 6/9, the superstructure (beams and supports above the deck) shows fair condition, with minor wear flagged for upkeep.
  • The substructure (piers and abutments) is in good condition (7/9), showing no significant deterioration.

How to read this record

IL 40 FAP 646 is in the federal Poor condition category. That is a component-based result, not a closure order.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Understand what Poor condition does and does not mean before drawing conclusions. Poor condition explained
  • Compare IL 40 FAP 646 against other structures in Bureau and across Illinois. Illinois bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for IL 40 FAP 646?

IL 40 FAP 646 in Bureau, Illinois has a deck rating of 4/9, superstructure rating of 6/9, and substructure rating of 7/9 on the FHWA's 0–9 scale.

How often is IL 40 FAP 646 inspected?

IL 40 FAP 646's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 1,100 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. IL 40 FAP 646 is currently shown as Poor condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for IL 40 FAP 646?

IL 40 FAP 646 has an NBI inventory load rating of 41.1 metric tons.

Who is responsible for maintaining IL 40 FAP 646?

IL 40 FAP 646 is owned and maintained by State Highway Agency.

How old is IL 40 FAP 646 and does age affect safety?

IL 40 FAP 646 was built in 1982, making it 44 years old.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Every figure on PlainBridge is rendered directly from federal source data, no number is typed in by an editor. This page draws directly on federal source data, no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error.