FHWA NBI 2024 Inspection record Public-domain dataset

TR 76

Carrying TR 76 over FLAT BRANCH

1.0 MI W HUMBOLT, Coles, Illinois

Data updated May 2026

FHWA NBI record, refreshed with each annual release.

Fair
23 t Inventory load rating

Bridge Snapshot: TR 76

The TR 76 bridge in Coles, Illinois carries TR 76 over FLAT BRANCH. It was built in 1909, making it 117 years old today. The structure is built primarily of prestressed concrete and spans 1 section, stretching 21.6 meters (71 feet) end to end. Daily traffic averages 175 vehicles, placing it in the lower-traffic tier of Illinois bridges. It is owned and maintained by Town/Township Highway Agency.

The latest FHWA inspection records show a deck rating of 6/9, superstructure at 6/9, substructure at 5/9. The weakest component sits in fair condition. No reported major component scores in the Poor range under the current federal condition thresholds. Its NBI inventory load rating is 22.7 metric tons.

Sourced from the FHWA National Bridge Inventory. See our methodology for refresh cadence and NBI release vintage.

How TR 76 compares

▼ 11.9
Load rating vs Illinois average (34.6 t)
Bottom 8%
Lower load rating than 92% of Illinois bridges
308
Bridges in Coles · 21 in Poor condition
TR 76 22.7 t
Illinois average 34.6 t

Live comparison across Illinois.

Historical Sufficiency Rating

PlainBridge-computed
69.1 / 100 - historical 50–79.9 band
Structural adequacy /55
35.2
Serviceability /30
22.0
Essentiality /15
15.0
Special reductions
−3.0

FHWA discontinued this calculated item; it does not determine current condition, funding eligibility, posting, or closure. How the historical reference is calculated.

Condition Ratings

Deck
6/9
Fair (5–6)
Superstructure
6/9
Fair (5–6)
Substructure
5/9
Fair (5–6)
Inventory Load Rating
22.7 t
NBI inventory level (metric tons)
Overall Condition
Fair

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Structural Details

Year Built
1909
Material
Prestressed Concrete
Number of Spans
1
Structure Length
21.6 m (71 ft)
Deck Width
6.4 m (21 ft)
Owner
Town/Township Highway Agency
Avg Daily Traffic
175 vehicles/day
Structure Number
015309100000000

Condition Analysis

  • The deck (driving surface) rates fair at 6/9, minor deterioration that routine maintenance should address.
  • The superstructure (beams and supports above the deck) is in fair condition (6/9), with minor deterioration that may require routine maintenance.
  • At 5/9, the substructure (piers and abutments) shows fair condition, with minor wear flagged for upkeep.

How to read this record

This page shows what the last federal inspection recorded, not whether TR 76 is safe to cross today. Here is how to use it.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Learn how the 0–9 condition scale and Good/Fair/Poor categories are defined. How condition ratings work
  • Compare TR 76 against other structures in Coles and across Illinois. Illinois bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for TR 76?

TR 76 in Coles, Illinois has a deck rating of 6/9, superstructure rating of 6/9, and substructure rating of 5/9 on the FHWA's 0–9 scale.

How often is TR 76 inspected?

TR 76's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 175 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. TR 76 is currently shown as Fair condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for TR 76?

TR 76 has an NBI inventory load rating of 22.7 metric tons.

Who is responsible for maintaining TR 76?

TR 76 is owned and maintained by Town/Township Highway Agency.

How old is TR 76 and does age affect safety?

TR 76 was built in 1909, making it 117 years old.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Every figure on PlainBridge is rendered directly from federal source data, no number is typed in by an editor. This page draws directly on federal source data, no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error.