FHWA NBI 2024 Inspection record Public-domain dataset

OFF PR 704

Carrying OFF PR 704 over OBISPO CREEK

9 KM NORTH EAST OF COAMO, Coamo, Puerto Rico

Data updated May 2026

FHWA NBI record, refreshed with each annual release.

Poor
13 t Inventory load rating

Bridge Snapshot: OFF PR 704

The OFF PR 704 bridge in Coamo, Puerto Rico carries OFF PR 704 over OBISPO CREEK. It was built in 1986, making it 40 years old today. The structure is built primarily of concrete continuous and spans 3 sections, stretching 14.1 meters (46 feet) end to end. Daily traffic averages 100 vehicles, placing it in the lower-traffic tier of Puerto Rico bridges. It is owned and maintained by City/Municipal Highway Agency.

The latest FHWA inspection records show a deck rating of 4/9, superstructure at 4/9, substructure at 5/9. The weakest component sits in poor condition. Because at least one major component scores 4 or lower, this bridge falls in FHWA's Poor condition category. That category is not a closure order. Its NBI inventory load rating is 12.7 metric tons.

Sourced from the FHWA National Bridge Inventory. See our methodology for refresh cadence and NBI release vintage.

How OFF PR 704 compares

▼ 23.4
Load rating vs Puerto Rico average (36.1 t)
Bottom 11%
Lower load rating than 89% of Puerto Rico bridges
30
Bridges in Coamo · 5 in Poor condition
OFF PR 704 12.7 t
Puerto Rico average 36.1 t

Live comparison across Puerto Rico.

Historical Sufficiency Rating

PlainBridge-computed
29.7 / 100 - historical 20–49.9 band
Structural adequacy /55
1.5
Serviceability /30
13.5
Essentiality /15
14.6
Special reductions
0

FHWA discontinued this calculated item; it does not determine current condition, funding eligibility, posting, or closure. How the historical reference is calculated.

Condition Ratings

Deck
4/9
Poor (1–4)
Superstructure
4/9
Poor (1–4)
Substructure
5/9
Fair (5–6)
Inventory Load Rating
12.7 t
NBI inventory level (metric tons)
Overall Condition
Poor

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Structural Details

Year Built
1986
Material
Concrete Continuous
Number of Spans
3
Structure Length
14.1 m (46 ft)
Deck Width
5.5 m (18 ft)
Owner
City/Municipal Highway Agency
Avg Daily Traffic
100 vehicles/day
Structure Number
019511

Condition Analysis

  • At 4/9, the deck (driving surface) is in poor shape, with advanced wear flagged for priority repair.
  • At 4/9, the superstructure (beams and supports above the deck) is in poor shape, with advanced wear flagged for priority repair.
  • The substructure (piers and abutments) is in fair condition (5/9), with minor deterioration that may require routine maintenance.

How to read this record

OFF PR 704 is in the federal Poor condition category. That is a component-based result, not a closure order.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Understand what Poor condition does and does not mean before drawing conclusions. Poor condition explained
  • Compare OFF PR 704 against other structures in Coamo and across Puerto Rico. Puerto Rico bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for OFF PR 704?

OFF PR 704 in Coamo, Puerto Rico has a deck rating of 4/9, superstructure rating of 4/9, and substructure rating of 5/9 on the FHWA's 0–9 scale.

How often is OFF PR 704 inspected?

OFF PR 704's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 100 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. OFF PR 704 is currently shown as Poor condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for OFF PR 704?

OFF PR 704 has an NBI inventory load rating of 12.7 metric tons.

Who is responsible for maintaining OFF PR 704?

OFF PR 704 is owned and maintained by City/Municipal Highway Agency.

How old is OFF PR 704 and does age affect safety?

OFF PR 704 was built in 1986, making it 40 years old.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Every figure on PlainBridge is rendered directly from federal source data, no number is typed in by an editor. This page draws directly on federal source data, no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error.