FHWA NBI 2024 Inspection record Public-domain dataset

CUBA RD

Carrying CUBA RD over OBERHALTZER DITCH

00.05 N OF GRABILL ROAD, Allen, Indiana

Data updated May 2026

FHWA NBI record, refreshed with each annual release.

Poor
29 t Inventory load rating

Bridge Snapshot: CUBA RD

The CUBA RD bridge in Allen, Indiana carries CUBA RD over OBERHALTZER DITCH. It was built in 1937, making it 89 years old today. It was last reconstructed in 2005, extending its service life. The structure is built primarily of concrete and spans 1 section, stretching 6.7 meters (22 feet) end to end. Daily traffic averages 1,150 vehicles, placing it in the moderately-trafficked tier of Indiana bridges. It is owned and maintained by County Highway Agency.

The latest FHWA inspection records show a deck rating of 4/9, superstructure at 4/9, substructure at 5/9. The weakest component sits in poor condition. A component scored 4 or below, placing this bridge in the federal Poor condition category rather than declaring it unsafe or closed. Its NBI inventory load rating is 28.5 metric tons.

Sourced from the FHWA National Bridge Inventory. See our methodology for refresh cadence and NBI release vintage.

How CUBA RD compares

▼ 7.1
Load rating vs Indiana average (35.6 t)
Bottom 21%
Lower load rating than 79% of Indiana bridges
601
Bridges in Allen · 41 in Poor condition
CUBA RD 28.5 t
Indiana average 35.6 t

Live comparison across Indiana.

Historical Sufficiency Rating

PlainBridge-computed
47.1 / 100 - historical 20–49.9 band
Structural adequacy /55
27.5
Serviceability /30
8.0
Essentiality /15
14.6
Special reductions
−3.0

FHWA discontinued this calculated item; it does not determine current condition, funding eligibility, posting, or closure. How the historical reference is calculated.

Condition Ratings

Deck
4/9
Poor (1–4)
Superstructure
4/9
Poor (1–4)
Substructure
5/9
Fair (5–6)
Inventory Load Rating
28.5 t
NBI inventory level (metric tons)
Overall Condition
Poor

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Structural Details

Year Built
1937
Last Reconstructed
2005
Material
Concrete
Number of Spans
1
Structure Length
6.7 m (22 ft)
Deck Width
8.0 m (26 ft)
Owner
County Highway Agency
Avg Daily Traffic
1,150 vehicles/day
Structure Number
0200325

Condition Analysis

  • The deck (driving surface) rates poor at 4/9, advanced deterioration that should be prioritized for repair.
  • At 4/9, the superstructure (beams and supports above the deck) is in poor shape, with advanced wear flagged for priority repair.
  • At 5/9, the substructure (piers and abutments) shows fair condition, with minor wear flagged for upkeep.

How to read this record

CUBA RD is in the federal Poor condition category. That is a component-based result, not a closure order.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Understand what Poor condition does and does not mean before drawing conclusions. Poor condition explained
  • Compare CUBA RD against other structures in Allen and across Indiana. Indiana bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for CUBA RD?

CUBA RD in Allen, Indiana has a deck rating of 4/9, superstructure rating of 4/9, and substructure rating of 5/9 on the FHWA's 0–9 scale.

How often is CUBA RD inspected?

CUBA RD's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 1,150 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. CUBA RD is currently shown as Poor condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for CUBA RD?

CUBA RD has an NBI inventory load rating of 28.5 metric tons.

Who is responsible for maintaining CUBA RD?

CUBA RD is owned and maintained by County Highway Agency.

How old is CUBA RD and does age affect safety?

CUBA RD was built in 1937, making it 89 years old and last reconstructed in 2005.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Every figure on PlainBridge is rendered directly from federal source data, no number is typed in by an editor. This page draws directly on federal source data, no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error.