FHWA NBI 2024 Inspection record Public-domain dataset

N2860

Carrying N2860 over CREEK

1. W 1.1 N OF US 277, Grady, Oklahoma

Data updated May 2026

FHWA NBI record, refreshed with each annual release.

Poor
15 t Inventory load rating

Bridge Snapshot: N2860

The N2860 bridge in Grady, Oklahoma carries N2860 over CREEK. It was built in 1928, making it 98 years old today. The structure is built primarily of steel and spans 1 section, stretching 12.4 meters (41 feet) end to end. Daily traffic averages 500 vehicles, placing it in the lower-traffic tier of Oklahoma bridges. It is owned and maintained by County Highway Agency.

The latest FHWA inspection records show a deck rating of 5/9, superstructure at 5/9, substructure at 4/9. The weakest component sits in poor condition. Because at least one major component scores 4 or lower, this bridge falls in FHWA's Poor condition category. That category is not a closure order. Its NBI inventory load rating is 14.5 metric tons.

Sourced from the FHWA National Bridge Inventory. See our methodology for refresh cadence and NBI release vintage.

How N2860 compares

▼ 17.9
Load rating vs Oklahoma average (32.4 t)
Bottom 5%
Lower load rating than 95% of Oklahoma bridges
446
Bridges in Grady · 31 in Poor condition
N2860 14.5 t
Oklahoma average 32.4 t

Live comparison across Oklahoma.

Historical Sufficiency Rating

PlainBridge-computed
27.6 / 100 - historical 20–49.9 band
Structural adequacy /55
5.4
Serviceability /30
8.0
Essentiality /15
14.3
Special reductions
0

FHWA discontinued this calculated item; it does not determine current condition, funding eligibility, posting, or closure. How the historical reference is calculated.

Condition Ratings

Deck
5/9
Fair (5–6)
Superstructure
5/9
Fair (5–6)
Substructure
4/9
Poor (1–4)
Inventory Load Rating
14.5 t
NBI inventory level (metric tons)
Overall Condition
Poor

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Structural Details

Year Built
1928
Material
Steel
Number of Spans
1
Structure Length
12.4 m (41 ft)
Deck Width
7.0 m (23 ft)
Owner
County Highway Agency
Avg Daily Traffic
500 vehicles/day
Structure Number
020580000000000

Condition Analysis

  • At 5/9, the deck (driving surface) shows fair condition, with minor wear flagged for upkeep.
  • The superstructure (beams and supports above the deck) rates fair at 5/9, minor deterioration that routine maintenance should address.
  • The substructure (piers and abutments) is in poor condition (4/9), showing advanced deterioration that may require priority repair.

How to read this record

N2860 is in the federal Poor condition category. That is a component-based result, not a closure order.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Understand what Poor condition does and does not mean before drawing conclusions. Poor condition explained
  • Compare N2860 against other structures in Grady and across Oklahoma. Oklahoma bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for N2860?

N2860 in Grady, Oklahoma has a deck rating of 5/9, superstructure rating of 5/9, and substructure rating of 4/9 on the FHWA's 0–9 scale.

How often is N2860 inspected?

N2860's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 500 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. N2860 is currently shown as Poor condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for N2860?

N2860 has an NBI inventory load rating of 14.5 metric tons.

Who is responsible for maintaining N2860?

N2860 is owned and maintained by County Highway Agency.

How old is N2860 and does age affect safety?

N2860 was built in 1928, making it 98 years old.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Every figure on PlainBridge is rendered directly from federal source data, no number is typed in by an editor. This page draws directly on federal source data, no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error.